Literature DB >> 19920306

The correlation between mass-averaged SAR and temperature elevation in the human head model exposed to RF near-fields from 1 to 6 GHz.

Akimasa Hirata1, Osamu Fujiwara.   

Abstract

In the present study, we investigate the relationship between the mass-averaged specific absorption rate (SAR) and temperature elevation in anatomically based Japanese head models due to the dipole antenna. A homogeneous cubical model is also used as a basis for the investigation. The frequency region considered is from 1 to 6 GHz. We focused on the averaging mass of SAR, which maximizes the correlation with local temperature elevation. An averaged SAR over 10 g was found to reasonably correlate with local temperature elevation even for frequencies from 3 to 6 GHz. The dominant factor influencing the correlation between mass-averaged SAR and temperature elevation is suggested to be the thermal diffusion length in biological tissue, together with the penetration depth of radio-frequency waves. The correlation of local temperature elevation to mass-averaged SAR is largely influenced by the blood perfusion rate, while at most 10% or less is due to the pinna, model inhomogeneity and the antenna position relative to the head model.

Entities:  

Mesh:

Year:  2009        PMID: 19920306     DOI: 10.1088/0031-9155/54/23/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Temperature elevation in the human brain and skin with thermoregulation during exposure to RF energy.

Authors:  Sachiko Kodera; Jose Gomez-Tames; Akimasa Hirata
Journal:  Biomed Eng Online       Date:  2018-01-08       Impact factor: 2.819

2.  Multiphysics and Thermal Response Models to Improve Accuracy of Local Temperature Estimation in Rat Cortex under Microwave Exposure.

Authors:  Sachiko Kodera; Jose Gomez-Tames; Akimasa Hirata; Hiroshi Masuda; Takuji Arima; Soichi Watanabe
Journal:  Int J Environ Res Public Health       Date:  2017-03-30       Impact factor: 3.390

3.  Comparison of 16-Channel Asymmetric Sleeve Antenna and Dipole Antenna Transceiver Arrays at 10.5 Tesla MRI.

Authors:  Myung Kyun Woo; Lance Delabarre; Matt Waks; Jingu Lee; Russell Luke Lagore; Steve Jungst; Andrea Grant; Yigitcan Eryaman; Kamil Ugurbil; Gregor Adriany
Journal:  IEEE Trans Med Imaging       Date:  2021-04-01       Impact factor: 10.048

4.  An Evaluation of Electromagnetic Exposure While Using Ultra-High Frequency Radiofrequency Identification (UHF RFID) Guns.

Authors:  Patryk Zradziński; Jolanta Karpowicz; Krzysztof Gryz; Victoria Ramos
Journal:  Sensors (Basel)       Date:  2019-12-30       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.