Literature DB >> 19918601

Analysis of translucency of skin by volume reflection for color formulation of facial prostheses.

Anke Korfage1, Peter C F Borsboomb, Pieter U Dijkstra, Robert P van Oort.   

Abstract

PURPOSE: A facial prosthesis demands a good visual match with the adjacent skin. Skin color and translucency must be mimicked by the prosthesis. Translucency can be defined as allowing the passage of light, yet diffusing it so as not to render the bodies beyond clearly visible, therefore being semi-transparent. The translucency of skin hampers color measurements of color meters recommended by the Commission Internationale de l'Eclairage (CIE) due to edge loss. The aim of this study was to analyze the translucency of skin at different body sites by measuring volume reflection in a cohort of Caucasian individuals.
MATERIALS AND METHODS: To analyze skin translucency, a volume reflection meter (VRM) was applied to the skin of the forehead, cheek, palm of the hand, and lower forearm. The VRM measures the volume reflection of a small incident light beam at three different distances from the incident beam. To describe the impact of translucency on skin color and the impact of volume reflection at different distances of an incident beam, the VRM spectra were converted into CIE L*a*b* coordinates.
RESULTS: VRM measurements were carried out on a cohort of 48 individuals during spring. The mean age was 40.8 years (+/- 11.7 years). Statistically significant interactions between body site, distance from the light source, and L*, a*, and b* values were found. L* values decreased and a* and b* values increased at longer distances from the incident light beam since the light path was increased.
CONCLUSION: Skin on the forehead, cheek, palm of the hand, and lower forearm each have their own specific volume reflection and thus, translucency, absorption, and scattering characteristics. These location-specific characteristics are due to known local differences in the skin's multilayered structure. For a good visual match between a facial prosthesis and the adjacent skin, volume reflection measurements of the skin close to the intended site of the prosthesis are necessary.

Mesh:

Year:  2009        PMID: 19918601

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  2 in total

1.  The Reproducibility and Applicability of an EFD(®) Dispenser in the Prosthetic Technology of Maxillofacial Prostheses.

Authors:  L Blokland; P C F Borsboom; M A Stokman; H Reintsema; R P van Oort
Journal:  J Indian Prosthodont Soc       Date:  2013-06-06

2.  The role of photobiomodulation when associated with microneedling in female pattern hair loss: A randomized, double blind, parallel group, three arm, clinical study protocol.

Authors:  Suzana Polonca da Silveira; Sandra Rojas Urquizas Moita; Silvia Vicente da Silva; Maria Fernanda Setúbal Destro Rodrigues; Daniela de Fátima Teixeira da Silva; Christiane Pavani
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.