Literature DB >> 19918596

Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up.

Johannes Schmitt1, Stefan Holst, Manfred Wichmann, Sven Reich, Matthias Gollner, Jorg Hamel.   

Abstract

PURPOSE: The aim of this prospective clinical trial was to evaluate the reliability of three- and four-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 3 years of clinical function.
MATERIALS AND METHODS: Thirty patients, each needing a posterior FPD to restore one or two missing teeth, were included in the study. Preparation guidelines were: occlusal reduction of 1.5 to 2 mm, axial reduction of 1.5 mm, and circumferential chamfer preparation placed 0.5 mm subgingivally. Frameworks were fabricated using a computer-aided design/computer-assisted manufacture technique. All FPDs were cemented with glass-ionomer cement. At baseline and 12, 24, and 36 months after cementation, survival and success of the zirconia framework and the ceramic veneer were evaluated. To analyze the effect of placement of an all-ceramic restoration on the gingival tissue, Gingival Index, Plaque Index, sulcus bleeding index, and pocket depth at abutment (test) and contralateral analogous teeth (control) were assessed. Data were analyzed by descriptive statistics, the Wilcoxon test, and the McNemar test.
RESULTS: Of the 30 initial subjects, 27 patients with 27 zirconia FPDs were examined after a mean testing period of 34.2 months. All FPDs were still in use and unfractured, resulting in a 100% survival rate for the frameworks. One FPD exhibited a major chip after 36 months. The cumulative success rate was 96.3%. No significant differences between the periodontal parameters of the test and control teeth were observed. The Plaque Index revealed significantly higher scores for mesial and distal control teeth at baseline and after 12 and 24 months for distal control teeth.
CONCLUSION: Posterior zirconia-based three- and four-unit FPDs present a reliable treatment modality after medium-term clinical use.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19918596

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  23 in total

1.  The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio.

Authors:  Bogna Stawarczyk; Mutlu Ozcan; Lubica Hallmann; Andreas Ender; Albert Mehl; Christoph H F Hämmerlet
Journal:  Clin Oral Investig       Date:  2012-02-23       Impact factor: 3.573

Review 2.  Performance of dental ceramics: challenges for improvements.

Authors:  E D Rekow; N R F A Silva; P G Coelho; Y Zhang; P Guess; V P Thompson
Journal:  J Dent Res       Date:  2011-01-11       Impact factor: 6.116

Review 3.  New Knowledge about Zirconium-Ceramic as a Structural Material in Fixed Prosthodontics.

Authors:  Davor Špehar; Marko Jakovac
Journal:  Acta Stomatol Croat       Date:  2015-06

4.  Three- to nine-year survival estimates and fracture mechanisms of zirconia- and alumina-based restorations using standardized criteria to distinguish the severity of ceramic fractures.

Authors:  Osvaldo D Moráguez; H W Anselm Wiskott; Susanne S Scherrer
Journal:  Clin Oral Investig       Date:  2015-05-20       Impact factor: 3.573

Review 5.  Dental Ceramics for Restoration and Metal Veneering.

Authors:  Yu Zhang; J Robert Kelly
Journal:  Dent Clin North Am       Date:  2017-10

6.  The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study.

Authors:  Seung-Ryong Ha; Sung-Hun Kim; Jung-Suk Han; Seung-Hyun Yoo; Se-Chul Jeong; Jai-Bong Lee; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

7.  Clinical performance and failures of zirconia-based fixed partial dentures: a review literature.

Authors:  Premwara Triwatana; Noppavan Nagaviroj; Chantana Tulapornchai
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

Review 8.  Clinical Performance of CAD/CAM All-Ceramic Tooth-Supported Fixed Dental Prostheses: A Systematic Review and Meta-Analysis.

Authors:  Babak Saravi; Andreas Vollmer; Maja Hartmann; Gernot Lang; Ralf-Joachim Kohal; Martin Boeker; Sebastian B M Patzelt
Journal:  Materials (Basel)       Date:  2021-05-20       Impact factor: 3.623

9.  Evaluation of Efficacy of Various Surface Conditioning Methods on the Repair Bond Strength of Composite to Different Fracture Types of Zirconia Ceramics.

Authors:  Serdar Polat; Emre Tokar; Neset Volkan Asar; Omer Kirmali
Journal:  Scanning       Date:  2021-05-21       Impact factor: 1.932

10.  Cold Atmospheric Plasma Improves Shear Bond Strength of Veneering Composite to Zirconia.

Authors:  Oskar Bunz; Paul Kalz; Carla I Benz; Ella A Naumova; Wolfgang H Arnold; Andree Piwowarczyk
Journal:  Dent J (Basel)       Date:  2021-05-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.