Literature DB >> 1991768

Sensitivity to titanium. A cause of implant failure?

P A Lalor1, P A Revell, A B Gray, S Wright, G T Railton, M A Freeman.   

Abstract

Tissues from five patients who underwent revision operations for failed total hip replacements were found to contain large quantities of particulate titanium. In four cases this metal must have come from titanium alloy screws used to fix the acetabular component; in the fifth case it may also have originated from a titanium alloy femoral head. Monoclonal antibody labelling showed abundant macrophages and T-lymphocytes, in the absence of B-lymphocytes, suggesting sensitisation to titanium. Skin patch testing with dilute solutions of titanium salts gave negative results in all five patients. However, two of them had a positive skin test to a titanium-containing ointment.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1991768

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  51 in total

1.  Choice of internal rigid fixation materials in the treatment of facial fractures.

Authors:  Mirko S Gilardino; Elliot Chen; Scott P Bartlett
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-03

2.  [Allergic reactions as differential diagnosis for periprosthetic infection].

Authors:  H Meyer; A Krüger; A Roessner; C H Lohmann
Journal:  Orthopade       Date:  2012-01       Impact factor: 1.087

3.  Factors to consider in joint prosthesis systems.

Authors:  Larry M Wolford
Journal:  Proc (Bayl Univ Med Cent)       Date:  2006-07

4.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 5.  The combined role of wear particles, macrophages and lymphocytes in the loosening of total joint prostheses.

Authors:  Peter A Revell
Journal:  J R Soc Interface       Date:  2008-11-06       Impact factor: 4.118

6.  Polycaprolactone scaffold as targeted drug delivery system and cell attachment scaffold for postsurgical care of limb salvage.

Authors:  Bin Sheng Wong; Swee-Hin Teoh; Lifeng Kang
Journal:  Drug Deliv Transl Res       Date:  2012-08       Impact factor: 4.617

Review 7.  Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis.

Authors:  Justin Paul Curtin; Minji Wang
Journal:  J Biol Inorg Chem       Date:  2017-05-17       Impact factor: 3.358

8.  Evidence for active antigen presentation by monocyte/macrophages in response to stimulation with particles: the expression of NFκB transcription factors and costimulatory molecules.

Authors:  Huwaidha Altaf; Peter A Revell
Journal:  Inflammopharmacology       Date:  2013-05-14       Impact factor: 4.473

9.  [Pathophysiology of posttraumatic osteitis].

Authors:  T Kälicke; F Kutscha-Lissberg; T M Frangen; G Muhr; S Arens
Journal:  Orthopade       Date:  2004-04       Impact factor: 1.087

10.  Preliminary experience with biodegradable implants for fracture fixation.

Authors:  Mandeep S Dhillon; Sharad Prabhakar; Chandiralingam Prasanna
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

View more