Accuracy of exercise electrocardiography in detecting physiologically significant coronary arterial lesions.

R F Wilson1, M L Marcus, B V Christensen, C Talman, C W White.   

Abstract

The accuracy of exercise electrocardiography in detecting a physiologically significant coronary artery stenosis has been assessed previously by comparing the exercise test with a coronary arteriogram. The inherent inaccuracy of visually determined percent diameter stenosis measurements might have lead to the conclusion that the exercise electrocardiogram was less accurate than it truly was. To determine the accuracy of the exercise electrocardiography in detecting a physiologically significant coronary stenosis, we studied 40 patients with one-vessel, one-lesion coronary artery disease, a normal resting electrocardiogram, and no hypertrophy or prior infarction. Each patient underwent exercise electrocardiography (Bruce protocol) that was interpreted as abnormal if the ST segment developed 0.1-mV or greater depression 80 msec after the J point. The physiological significance of each coronary stenosis was assessed by measuring of coronary flow reserve (peak divided by resting blood flow velocity) in the stenotic artery using a Doppler catheter and intracoronary papaverine (normal, 3.5 or greater peak/resting velocity). The percent diameter and percent area stenosis produced by each lesion were determined using quantitative angiography (Brown/Dodge method). Of the 17 patients with reduced coronary flow reserve (3.5 or greater peak/resting blood flow velocity) in the stenotic artery, 14 had an abnormal exercise electrocardiogram (sensitivity, 0.82; 95% confidence interval, 0.70-0.94). Conversely, 20 of 23 patients with normal coronary flow reserves had normal exercise tests (specificity, 0.87; 95% confidence interval, 0.77-0.97). The exercise electrocardiogram was abnormal in each of 11 patients with markedly reduced coronary flow reserve (less than 2.5 peak/resting velocity) and in three of six patients with moderately reduced reserve (2.5-3.4 peak/resting velocity). The products of systolic blood pressure and heart rate at peak exercise were significantly correlated with coronary reserve in patients with truly abnormal exercise tests. In comparison, the sensitivity (0.61; 95% confidence interval, 0.46-0.76) and specificity (0.73; 95% confidence interval, 0.60-0.86) of exercise electrocardiography in detecting a 60% or greater diameter stenosis may be significantly lower (p less than 0.05). Exercise electrocardiography, therefore, was a good predictor of the physiological significance (assessed by coronary flow reserve) of a coronary stenosis in patients with a normal resting electrocardiogram and no hypertrophy or prior infarction. Its value in a broader and larger patient population will require further study. These results, however, underscore the importance of a physiological gold standard in assessing the accuracy of noninvasive studies for detecting coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1991365     DOI: 10.1161/01.cir.83.2.412

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  9 in total

Review 1.  Validation of noninvasive studies for detecting coronary artery disease: beauty versus blood flow.

Authors:  R F Wilson
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

2.  A descriptive analysis of exercise tolerance test at seremban hospital : an audit for the year 2001.

Authors:  Abdul Latiff Mohamed; Chan Chee Nee; Ahmed Azzad
Journal:  Malays J Med Sci       Date:  2004-07

3.  Concerning falsely negative and falsely positive electrocardiographic responses to exercise.

Authors:  L S Gettes; P Sapin
Journal:  Br Heart J       Date:  1993-09

4.  Stress echocardiography: time for critical reappraisal.

Authors:  P K Mazeika; P Nihoyannopoulos; C M Oakley
Journal:  Br Heart J       Date:  1993-09

5.  Failure of right precordial electrocardiography during stress testing to identify coronary artery disease.

Authors:  S Bokhari; D K Blood; S R Bergmann
Journal:  J Nucl Cardiol       Date:  2001 May-Jun       Impact factor: 5.952

6.  Accuracy of exercise testing in the assessment of the severity of myocardial ischemia as determined by means of technetium-99m tetrofosmin SPECT scintigraphy.

Authors:  A R Galassi; S Azzarelli; L Lupo; C Mammana; R Foti; C Tamburino; S Musumeci; G Giuffrida
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

7.  What percent luminal stenosis should be used to define angiographic coronary artery disease for noninvasive test evaluation?

Authors:  Michael Lipinski; Dat Do; Anthony Morise; Victor Froelicher
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-04       Impact factor: 1.468

8.  Usefulness of pulse pressure for the detection of extent and severity of coronary artery disease in type 2 diabetic patients with silent myocardial ischaemia at exercise stress test.

Authors:  S Bacci; M Villella; A Villella; A Rauseo; T Langialonga; V Trischitta
Journal:  Diabetologia       Date:  2005-05-04       Impact factor: 10.122

9.  The challenge of asymptomatic coronary artery disease in aircrew; detecting plaque before the accident.

Authors:  Gary Gray; Eddie D Davenport; Dennis Bron; Rienk Rienks; Joanna d'Arcy; Norbert Guettler; Olivier Manen; Thomas Syburra; Edward D Nicol
Journal:  Heart       Date:  2019-01       Impact factor: 5.994