Literature DB >> 19910809

A comparison of 2 optical timing systems designed to measure flight time and contact time during jumping and hopping.

Laurent Bosquet1, Nicolas Berryman, Olivier Dupuy.   

Abstract

This study was designed to investigate the interchangeability of 2 commercial optical timing systems for measuring flight time and contact time during jumping and hopping. Seventy-three physical education students (33 men and 40 women) participated in this study. They were instructed to perform 3 jump protocols (squat jump, countermovement jump, and countermovement jump free arms) and a hopping test (10 seconds with straight legs at a frequency of 2 Hz). Flight time and contact time were measured with 2 optical timing systems (Optojump, Microgate, Italia and IR-mat, Ergotest, Sweden), consisting of 2 bars placed opposite to each other. Both systems trigger a timer with a precision of 1 millisecond each time the infrared light is interrupted by the feet. Jump height was given by the systems, whereas leg stiffness was computed from contact time and flight time. Flight time was higher when measured with the IR-mat (bias +/- 95% LOA [limits of agreement] = 5 +/- 14 ms, p < 0.001). This difference was trivial (effect size <0.2) and clinically meaningless. The high correlation between sets of data (r = 0.99) together with narrow 95% LOA (3%) support the interchangeability of both systems to measure flight time. Similar results were found with contact time (bias +/- 95% LOA = 8 +/- 23 ms, p < 0.001, effect size <0.2 and r = 0.99), with the exception that it was the Optojump that provided the higher values. These trivial but significant differences between both systems had minor impact on jumping height (bias +/- 95% LOA = 0.6 +/- 1.7 cm, p < 0.001), effect size <0.2 and r = 0.99), and stiffness (bias +/- 95% LOA = 0.8 +/- 1.4 N.m.kg, p < 0.001, effect size <0.2 and r = 0.98). We concluded that both systems can be used interchangeably.

Entities:  

Mesh:

Year:  2009        PMID: 19910809     DOI: 10.1519/JSC.0b013e3181b1f4ff

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  11 in total

Review 1.  Physical and physiological profiles of taekwondo athletes.

Authors:  Craig A Bridge; Jonatas Ferreira da Silva Santos; Helmi Chaabène; Willy Pieter; Emerson Franchini
Journal:  Sports Med       Date:  2014-06       Impact factor: 11.136

2.  Potential Energy as an Alternative for Assessing Lower Limb Peak Power in Children: A Bayesian Hierarchical Analysis.

Authors:  Jorge R Fernandez-Santos; Jose V Gutierrez-Manzanedo; Pelayo Arroyo-Garcia; Jose Izquierdo-Jurado; Jose L Gonzalez-Montesinos
Journal:  Int J Environ Res Public Health       Date:  2022-05-22       Impact factor: 4.614

3.  Power of counter movement jumps with external load--coherence of three assessment methods.

Authors:  Marie Hilmersson; Ida Edvardsson; Åsa B Tornberg
Journal:  BMC Res Notes       Date:  2015-04-16

4.  Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System.

Authors:  Robin Healy; Ian C Kenny; Andrew J Harrison
Journal:  J Hum Kinet       Date:  2016-12-15       Impact factor: 2.193

Review 5.  A review of the physiological and psychological health and wellbeing of naval service personnel and the modalities used for monitoring.

Authors:  Cliodhna Sargent; Cormac Gebruers; Jim O'Mahony
Journal:  Mil Med Res       Date:  2017-01-18

6.  The Use of an Optical Measurement System to Monitor Sports Performance.

Authors:  Eric D Magrum; John P Wagle; Brad H DeWeese; Kimitake Sato; Michael H Stone
Journal:  Sports (Basel)       Date:  2018-02-17

7.  Using Portable Force Plates to Assess Vertical Jump Performance: A Metrological Appraisal.

Authors:  François Raymond; Benoit Lussier; François Dugas; Mathieu Charbonneau; Félix Croteau; Cory Kennedy; Nicolas Berryman
Journal:  Sports (Basel)       Date:  2018-11-19

8.  Changes of reaction time and blood lactate concentration of elite volleyball players during a game.

Authors:  Dariusz Mroczek; Adam Kawczyński; Jan Chmura
Journal:  J Hum Kinet       Date:  2011-07-04       Impact factor: 2.193

9.  Reliability and validity of an accele-rometric system for assessing vertical jumping performance.

Authors:  M-A Choukou; G Laffaye; R Taiar
Journal:  Biol Sport       Date:  2014-01-22       Impact factor: 2.806

10.  The validity and reliability of the "My Jump App" for measuring jump height of the elderly.

Authors:  Rejane Maria Cruvinel-Cabral; Iransé Oliveira-Silva; André Ricarte Medeiros; João Gustavo Claudino; Pedro Jiménez-Reyes; Daniel A Boullosa
Journal:  PeerJ       Date:  2018-10-15       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.