| Literature DB >> 19910156 |
De-Kun Li1, Bei Yan, Zheng Li, Ersheng Gao, Maohua Miao, Dongming Gong, XiaoPing Weng, Jeannette R Ferber, Wei Yuan.
Abstract
We conducted a population-based case-control study among healthy sperm donors to study exposure to magnetic fields (MFs) and poor sperm quality. All participants wore a meter to capture daily MF exposure. After controlling for confounders, compared to those with lower MF exposure, those whose 90th percentile MF level > or = 1.6mG had a two-fold increased risk of abnormal sperm motility and morphology (odds ratio (OR): 2.0, 95% confidence interval (CI): 1.0-3.9). Increasing duration of MF exposure above 1.6 mG further increased the risk (p=0.03 for trend test). Importantly, the association and dose-response relationship were strengthened when restricted to those whose measurement day reflected their typical day of the previous 3 months (a likely period of spermatogenesis). Age-adjusted Spearman Rank Order Correlations showed an inverse correlation between MF exposure and all semen parameters. Our study provides some evidence for the first time that MF exposure may have an adverse effect on sperm quality. Copyright 2009 Elsevier Inc. All rights reserved.Entities:
Mesh:
Year: 2009 PMID: 19910156 DOI: 10.1016/j.reprotox.2009.09.004
Source DB: PubMed Journal: Reprod Toxicol ISSN: 0890-6238 Impact factor: 3.143