Literature DB >> 19909386

Results of short-term and long-term pulmonary vein isolation for paroxysmal atrial fibrillation using duty-cycled bipolar and unipolar radiofrequency energy.

Marcus Wieczorek1, Reinhard Hoeltgen, Elvan Akin, Ali Reza Salili, Hakan Oral, Fred Morady.   

Abstract

BACKGROUND: Electrical disconnection of the pulmonary veins (PV) plays an important role in the ablation of paroxysmal atrial fibrillation (AF). Antral ablation using a conventional steerable ablation catheter often is technically challenging and time consuming.
METHODS: Eighty-eight patients (mean age 58 +/- 11 years) with symptomatic paroxysmal AF underwent ablation with a circular mapping/ablation decapolar catheter (PVAC). Ablation was performed in the antral region of the PVs with a power-modulated bipolar/unipolar radiofrequency (RF) generator using 8-10 W delivered simultaneously through 2-10 electrodes, as selected by the operator. Seven-day Holter monitor recordings were performed off antiarrhythmic drugs at 3-, 6-, and 12-month follow-up, and patients were requested to visit the hospital in the event of ongoing palpitations. All follow-up patients were divided into 2 groups: Group 1 with a follow-up of less than 1 year and group 2 patients completing a 1-year follow-up.
RESULTS: Overall, 338 of 339 targeted PVs (99%) were isolated with the PVAC with a mean of 24 +/- 9 RF applications per patient, a mean total procedure time of 125 +/- 28 minutes, and a mean fluoroscopy time of 21 +/- 13 minutes. Freedom from AF off antiarrhythmic drugs was found in 82 and 79% of group 1 and group 2 patients, respectively. No procedure-related complications were observed.
CONCLUSION: PV isolation by duty-cycled unipolar/bipolar RF ablation can be effectively and safely performed with a circular, decapolar catheter. Twelve-month follow-up data compare favorably with early postablation results, indicating stable effects over time.

Entities:  

Mesh:

Year:  2009        PMID: 19909386     DOI: 10.1111/j.1540-8167.2009.01640.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  20 in total

1.  Point-by-point pulmonary vein antrum isolation guided by intracardiac echocardiography and 3D mapping and duty-cycled multipolar AF ablation: effect of multipolar ablation on procedure duration and fluoroscopy time.

Authors:  Yaariv Khaykin; Lauren Zarnett; Daniel Friedlander; Zaev A Wulffhart; Bonnie Whaley; David Giewercer; Bernice Tsang; Atul Verma
Journal:  J Interv Card Electrophysiol       Date:  2012-03-11       Impact factor: 1.900

Review 2.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

3.  Ablation of atrial fibrillation: single-shot techniques poised to dominate rhythm control strategies/the future is here.

Authors:  Antonis S Manolis
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

4.  Reduction of radiation exposure during ablation of atrial fibrillation.

Authors:  Ralph Schneider; Jörg Lauschke; Cindy Schneider; Tina Tischer; Aenne Glass; Dietmar Bänsch
Journal:  Herz       Date:  2015-05-20       Impact factor: 1.443

5.  Prevalence and predictors of complications of radiofrequency catheter ablation for atrial fibrillation.

Authors:  Timir S Baman; Krit Jongnarangsin; Aman Chugh; Arisara Suwanagool; Aurelie Guiot; Arin Madenci; Spencer Walsh; Karl J Ilg; Sanjaya K Gupta; Rakesh Latchamsetty; Suveer Bagwe; James D Myles; Thomas Crawford; Eric Good; Frank Bogun; Frank Pelosi; Fred Morady; Hakan Oral
Journal:  J Cardiovasc Electrophysiol       Date:  2011-01-15

Review 6.  Pulmonary Vein Isolation with the Multipolar nMARQ™ Ablation Catheter: Efficacy And Safety In Acute And Long-Term Follow Up.

Authors:  Johannes Siebermair; Michelle Silver; Reza Wakili
Journal:  J Atr Fibrillation       Date:  2017-04-30

Review 7.  Silent Cerebral Embolism during Atrial Fibrillation Ablation:Pathophysiology, Prevention and Management.

Authors:  Matteo Anselmino; Mario Matta; Elisabetta Toso; Federico Ferraris; Davide Castagno; Marco Scaglione; Federico Cesarani; Riccardo Faletti; Fiorenzo Gaita
Journal:  J Atr Fibrillation       Date:  2013-08-31

8.  First results and follow-up of a second-generation circular mapping and ablation catheter.

Authors:  Stefan Weber; Martin Höher; Dominik Schultes
Journal:  J Interv Card Electrophysiol       Date:  2016-05-26       Impact factor: 1.900

9.  Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode.

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Shahram Tajtaraghi; Wolfgang Lawrenz; Michael Lukat
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

10.  Long-term outcomes (>2 years) of atrial fibrillation ablation using a multi-electrode ablation catheter in patients with paroxysmal atrial fibrillation.

Authors:  Khang-Li Looi; Parag Gajendragadkar; Tamer Taha; Maros Elsik; Elizabeth Scully; Patrick Heck; Simon Fynn; Munmohan Virdee; David Begley
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900