Evaluation of bone impingement prediction in pre-operative planning for shoulder arthroplasty.

P R Krekel1, P W de Bruin, E R Valstar, F H Post, P M Rozing, C P Botha.   

Abstract

In shoulder arthroplasty, malpositioning of prostheses often leads to reduced postoperative range of motion (ROM) and complications such as impingement, loosening, and dislocation. Furthermore, the risk of impingement complications increases when reverse total prostheses are used. For this purpose a pre-operative planning system was developed that enables surgeons to perform a virtual shoulder replacement procedure. The present authors' pre-operative planning system simulates patient-specific bone-determined ROM meant to reduce the risk of impingement complications and to improve the ROM of patients undergoing shoulder replacement surgery. This paper describes a validation experiment with the purpose of ratifying the clinical applicability and usefulness of the ROM simulation module for shoulder replacement surgery. The experiment was performed on cadaveric shoulders. A data connection was set up between the software environment and an existing intra-operative guidance system to track the relative positions of the bones. This allowed the patient-specific surface models to be visualized within the software for the position and alignment of the tracked bones. For both shoulders, ROM measurements were recorded and tagged with relevant information such as the type of prosthesis and the type of movement that was performed. The observed ROM and occurrences of impingement were compared with the simulated equivalents. The median deviation between observed impingement angles and simulated impingement angles was -0.30 degrees with an interquartile range of 5.20 degrees (from -3.40 degrees to 1.80 degrees). It was concluded that the ROM simulator is sufficiently accurate to fulfil its role as a supportive instrument for orthopaedic surgeons during shoulder replacement surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19908420     DOI: 10.1243/09544119JEIM531

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Combining femoral and acetabular parameters in femoroacetabular impingement: the omega surface.

Authors:  Heinse Bouma; Tom Hogervorst; Emanuel Audenaert; Paulien van Kampen
Journal:  Med Biol Eng Comput       Date:  2015-10-07       Impact factor: 2.602

2.  ArthroPlanner: a surgical planning solution for acromioplasty.

Authors:  Caecilia Charbonnier; Sylvain Chagué; Bart Kevelham; Delphine Preissmann; Frank C Kolo; Olivier Rime; Alexandre Lädermann
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-02-09       Impact factor: 2.924

3.  Simulation of bone-determined range of motion in proximal humeral fractures.

Authors:  Addie Majed; Tanujan Thangarajah; Peter Krekel; Rob Nelissen; Peter Reilly; Anthony Bull; Roger Emery
Journal:  Shoulder Elbow       Date:  2017-06-13

4.  Femoroacetabular impingement and its implications on range of motion: a case report.

Authors:  Peter R Krekel; Anne Jh Vochteloo; Rolf M Bloem; Rob Ghh Nelissen
Journal:  J Med Case Rep       Date:  2011-04-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.