Literature DB >> 19907894

Reliability, technical error of measurements and validity of instruments for nutritional status assessment of adults in Malaysia.

A Geeta1, H Jamaiyah, M N Safiza, G L Khor, C C Kee, A Z Ahmad, S Suzana, R Rahmah, A Faudzi.   

Abstract

INTRODUCTION: The Third National Health and Morbidity Survey Malaysia 2006 includes a nutritional status assessment of children. This study aimed to assess the inter- and intra-examiner reliability, the technical error of measurement and the validity of instruments for measuring weight, height and waist circumference.
METHODS: A convenience sample of 130 adults working in a selected office setting was chosen to participate in the study, subject to the inclusion and exclusion study criteria. Two public health nurses, trained to follow a standard protocol, obtained the weight, height and waist circumference measurements. The weight was measured using the Tanita HD-318 digital weighing scale to the nearest 0.1 kg, and Seca Beam Scale to the nearest 0.01 kg. The height was measured using the Seca Bodymeter 206 and Stadiometer, both to the nearest 0.1 cm. The waist circumference was measured using the Seca circumference measuring tape S 201, to the nearest 0.1 cm.
RESULTS: The intra-examiner reliability in descending order was weight and height followed by waist circumference. The height measurement, on average, using the test instrument, reported a recording of 0.4 cm higher than the reference instrument, with the upper and lower limits at 2.5 cm and 1.6 cm, respectively. The technical error of measurement and coefficient of variation of weight and height for both inter-examiner and intra-examiner measurements were all within acceptable limits (below five percent).
CONCLUSION: The findings of this study suggest that weight, height and waist circumference measured in adults aged 18 years and above, using the respective above mentioned instruments, are reliable and valid for use in a community survey. Limiting the number of examiners, especially for waist circumference measurements, would yield a higher degree of reliability and validity.

Entities:  

Mesh:

Year:  2009        PMID: 19907894

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  12 in total

1.  Reliability of periocular anthropometry using three-dimensional digital stereophotogrammetry.

Authors:  Yongwei Guo; Alexander C Rokohl; Friederike Schaub; Xiaoyi Hou; Jinhua Liu; Yue Ruan; Renbing Jia; Konrad R Koch; Ludwig M Heindl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-08-12       Impact factor: 3.117

2.  Application of global positioning system methods for the study of obesity and hypertension risk among low-income housing residents in New York City: a spatial feasibility study.

Authors:  Dustin T Duncan; Seann D Regan; Donna Shelley; Kristen Day; Ryan R Ruff; Maliyhah Al-Bayan; Brian Elbel
Journal:  Geospat Health       Date:  2014-11       Impact factor: 1.212

3.  Reliability and practicality of measuring waist circumference to monitor cardiovascular risk among community mental health center patients.

Authors:  Jessica Barber; Laura Palmese; Lydia A Chwastiak; Joseph C Ratliff; Erin L Reutenauer; Michel Jean-Baptiste; Cenk Tek
Journal:  Community Ment Health J       Date:  2013-01-10

4.  Musculoskeletal sequelae in patients with obstetric fistula - a case-control study.

Authors:  Merete Kolberg Tennfjord; Mulu Muleta; Torvid Kiserud
Journal:  BMC Womens Health       Date:  2014-11-08       Impact factor: 2.809

5.  The association of quantitative insulin sensitivity indices (HOMA-IR and QUICKI) with anthropometric and cardiometabolic indicators in adolescents.

Authors:  Yaser Mirzaalian; Mozhgan Nourian; Maryam Gholamalizadeh; Saeid Doaei; Mahshid Hatami; Akbar Hassanzadeh; Gholamreza Askari; Raheleh Farahi
Journal:  Arch Med Sci Atheroscler Dis       Date:  2019-04-09

6.  Screening and assessment tools for early detection of malnutrition in hospitalised children: a systematic review of validation studies.

Authors:  Petra Klanjsek; Majda Pajnkihar; Natasa Marcun Varda; Petra Povalej Brzan
Journal:  BMJ Open       Date:  2019-05-27       Impact factor: 2.692

7.  Relationship Between Physical Activity, Coronary Artery Disease Risk Factors and Musculoskeletal Injuries in the City of Cape Town Fire and Rescue Service.

Authors:  Jaron Ras; Lloyd Leach
Journal:  Inquiry       Date:  2022 Jan-Dec       Impact factor: 1.730

8.  Elevated arterial blood pressure and body mass index among Nigerian preschool children population.

Authors:  Odutola I Odetunde; Emeka E Neboh; Josephat M Chinawa; Henrietta U Okafor; Oluwatoyin A Odetunde; Osita U Ezenwosu; Uchenna Ekwochi
Journal:  BMC Pediatr       Date:  2014-03-04       Impact factor: 2.125

9.  Factors associated with the severity of hypertension among Malaysian adults.

Authors:  Balkish Mahadir Naidu; Muhammad Fadhli Mohd Yusoff; Sarimah Abdullah; Kamarul Imran Musa; Najib Majdi Yaacob; Maria Safura Mohamad; Norhafizah Sahril; Tahir Aris
Journal:  PLoS One       Date:  2019-01-03       Impact factor: 3.240

10.  A randomized controlled trial comparing the clinical efficacy and cost-effectiveness of eye movement desensitization and reprocessing (EMDR) and integrated EMDR-Dialectical Behavioural Therapy (DBT) in the treatment of patients with post-traumatic stress disorder and comorbid (Sub)clinical borderline personality disorder: study design.

Authors:  Aishah Snoek; Aartjan T F Beekman; Jack Dekker; Inga Aarts; Gerard van Grootheest; Matthijs Blankers; Chris Vriend; Odile van den Heuvel; Kathleen Thomaes
Journal:  BMC Psychiatry       Date:  2020-08-06       Impact factor: 3.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.