Literature DB >> 1989948

Hand dose measurements in interventional radiology.

J P Felmlee1, P F McGough, R L Morin, K L Classic.   

Abstract

Measurements of radiation dose to the hand were conducted using TLD ring badges for individual interventional radiology cases. Results from over 30 examinations (including transhepatic cholangiograms and biliary and nephrostomy procedures) conducted by four radiologists using identical equipment show an average hand dose of 1.5 mGy (150 mrad) per procedure. Hand dose varied inversely with distance from the patient. Due to variable hand positions during clinical examinations, fluoroscopic time was not found to be a good indicator of hand dose.

Entities:  

Mesh:

Year:  1991        PMID: 1989948     DOI: 10.1097/00004032-199102000-00015

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  3 in total

Review 1.  Personal dosimetry for interventional operators: when and how should monitoring be done?

Authors:  C J Martin
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study.

Authors:  Uwe Häusler; Renate Czarwinski; Gunnar Brix
Journal:  Eur Radiol       Date:  2009-04-07       Impact factor: 5.315

3.  Level of knowledge on radiation exposure and compliance to wearing protective equipment: where do endourologists stand? An ESUT/EULIS survey.

Authors:  Lazaros Tzelves; Bhaskar Somani; Thomas Knoll; Guido Kamphuis; Kemal Sarica; C Seitz; E Liatsikos; Andreas Skolarikos
Journal:  World J Urol       Date:  2019-05-15       Impact factor: 4.226

  3 in total