Literature DB >> 19899040

A method for the non-invasive assessment of chest wall growth in pectus excavatum patients.

P-Y Chang1, C-H Chang, J-Y Lai, J-C Chen, D-B Perng, Q Zeng.   

Abstract

INTRODUCTION: Various scales and measurement methods including X-rays and computed tomography (CT) have been used to quantify the degree of deformity in pectus excavatum. This study describes a non-invasive method for recording the deviation of the anterior chest wall (ACW) in pectus excavatum (PE) patients. Data obtained using this non-invasive method were compared with CT data.
MATERIALS AND METHODS: Twenty-one patients treated at our institutions between June 2008 and February 2009 were enrolled in this study. All patients underwent CT and thermal plastic strip measurement. A thermal plastic strip was positioned and taped to the supine patient's ACW at the skin level from the posterior axillary line, over the depressed sternum, to the contralateral posterior axillary line and used to create a casting of the ACW.
RESULTS: The funnel index (FI) was defined as the width of the ACW divided by its height; the concave index (CI) was defined as the breadth of the depressed area of the funnel chest divided by its depth. Pearson's correlation coefficient was used to compare the FI and CI obtained with the thermal plastic strip method and with CT; measurements obtained with both methods were found to correlate well (FI: r (2)=0.965; CI: r (2)=0.947).
CONCLUSIONS: The thermal plastic strip measurement method provides a two-dimensional record of the shape of the anterior chest wall. The measurement can be repeated, does not involve the patient being exposed to radiation, and offers a good longitudinal assessment of chest wall growth in PE patients.

Entities:  

Mesh:

Year:  2009        PMID: 19899040     DOI: 10.1055/s-0029-1241819

Source DB:  PubMed          Journal:  Eur J Pediatr Surg        ISSN: 0939-7248            Impact factor:   2.191


  4 in total

1.  Comparison of Haller index values calculated with chest radiographs versus CT for pectus excavatum evaluation.

Authors:  Geetika Khanna; Alok Jaju; Steven Don; Tim Keys; Charles F Hildebolt
Journal:  Pediatr Radiol       Date:  2010-05-15

2.  The vacuum bell for conservative treatment of pectus excavatum: the Basle experience.

Authors:  Frank-Martin Haecker
Journal:  Pediatr Surg Int       Date:  2011-06       Impact factor: 1.827

3.  Radiologic factors related to double-bar insertion in minimal invasive repair of pectus excavatum.

Authors:  Ki Hwan Kim; Ki Yeol Lee; Jung Bok Lee; Kyung-Sook Yang; Jinwook Hwang; Bo Kyung Je; Hyung Joo Park
Journal:  World J Pediatr       Date:  2014-11-22       Impact factor: 2.764

4.  Thoracic shape changes in newborns due to their position.

Authors:  Serena de Gelidi; Andy Bardill; Nima Seifnaraghi; Yu Wu; Andreas Demosthenous; Marika Rahtu; Merja Kallio; Richard Bayford
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.