Literature DB >> 19895876

Effects of implant diameter, drug loading and end-capping on praziquantel release from PCL implants.

Changyan Li1, Liang Cheng, Yaqiong Zhang, Shengrong Guo, Weiping Wu.   

Abstract

Praziquantel (PZQ)-loaded poly(epsilon-caprolactone) (PCL) cylindrical implants were fabricated and characterized. Implant diameter (3, 4 and 8mm), drug loading (25% and 50%), and the end-capping were investigated to evaluate their effects on drug release. The evolution of implants with release time was conducted in terms of implant microstructure, crystallinity, drug content and molecular weight of PCL. The results showed that drug release was fastest for the implant with a diameter of 3mm and slowest for the implant with a diameter of 8mm; drug release from the implant with a drug content of 50% was faster than that from the implant with a drug content of 25%; the release of PZQ from the end-capped implants was slightly slower than that from the corresponding end-uncapped implants. The effect of drug loadings on PZQ release was related with diameter of the implants and the effect was weakened as diameter of the implants increased. The drug release data for all the implants were best fitted with Ritger-Peppas model, therefore Fickian diffusion was the predominant release mechanism. The evolution of implants with release time verified that PZQ was gradually released from the exterior to the interior of the implants. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19895876     DOI: 10.1016/j.ijpharm.2009.10.046

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  5 in total

1.  Evaluation of two polymeric blends (EVA/PLA and EVA/PEG) as coating film materials for paclitaxel-eluting stent application.

Authors:  Xi Liu; Lei Lei; Jing-Wen Hou; Mu-Fei Tang; Sheng-Rong Guo; Zhong-Min Wang; Ke-Min Chen
Journal:  J Mater Sci Mater Med       Date:  2011-01-08       Impact factor: 3.896

2.  Development and in vitro-in vivo evaluation of polymeric implants for continuous systemic delivery of curcumin.

Authors:  Shyam S Bansal; Manicka V Vadhanam; Ramesh C Gupta
Journal:  Pharm Res       Date:  2011-02-11       Impact factor: 4.200

3.  Development and evaluation of sustained-release etoposide-loaded poly(ε-caprolactone) implants.

Authors:  Ana Gabriela Reis Solano; Adriana de Fátima Pereira; Flavia Carmo Horta Pinto; Letícia Gonçalves Resende Ferreira; Leandro Augusto de Oliveira Barbosa; Silvia Ligório Fialho; Patrícia Santiago de Oliveira Patricio; Armando da Silva Cunha; Gisele Rodrigues da Silva; Gérson Antônio Pianetti
Journal:  AAPS PharmSciTech       Date:  2013-05-11       Impact factor: 3.246

4.  Enhanced antitumor efficacy of poly(D,L-lactide-co-glycolide)-based methotrexate-loaded implants on sarcoma 180 tumor-bearing mice.

Authors:  Li Gao; Lunyang Xia; Ruhui Zhang; Dandan Duan; Xiuxiu Liu; Jianjian Xu; Lan Luo
Journal:  Drug Des Devel Ther       Date:  2017-10-20       Impact factor: 4.162

5.  The improved antitumor efficacy of continuous intratumoral chemotherapy with cisplatin-loaded implants for the treatment of sarcoma 180 tumor-bearing mice.

Authors:  Li Gao; Shang Cai; Awei Cai; Yang Zhao; Tangbing Xu; Yan Ma; Yan Xu; Yuan Wang; Hao Wang; Yong Hu
Journal:  Drug Deliv       Date:  2019-12       Impact factor: 6.419

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.