INTRODUCTION: The occurrence of accelerated junctional rhythm (JR) during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT) is frequent. The aim of the present study was to compare the occurrence of JR during magnetic remote catheter ablation to the conventional manual ablation. METHODS AND
RESULTS: Twenty six patients (males: seven; age: 51 + or - 15 years) underwent slow pathway ablation with magnetic navigation (MN) system (Niobe, Stereotaxis Inc., St. Louis, MO, USA) and were compared to a control group of 11 patients (males: three; age: 53 + or - 16 years) treated with conventional manual ablation. A 4-mm nonirrigated tip catheter was used in both groups with a maximum of 30 W and 60 degrees C. Acute success was obtained in all patients. In the MN group, three patients out of 24 had no junctional beat (JB) at all and seven patients had 10 or less JB. In contrast, in the conventional group no patient had less than 10 JB. The mean number of JB in the MN group was 66 + or - 94.9 (0-410) and 200 + or - 243.1 (43-914) in the control group (P = 0.019). In the MN group one patient had a first-degree atrioventricular block. No other complication occurred.
CONCLUSIONS: Magnetic remote catheter ablation of AVNRT is effective and is associated with less JB than the manual conventional technique. Therefore, JB may not be considered as a mandatory indicator for successful AVNRT ablation with MN system.

Entities:  

Mesh:

Year:  2009        PMID: 19895412     DOI: 10.1111/j.1540-8159.2009.02592.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  An approach to left septal slow pathway ablation.

Authors:  Demosthenes G Katritsis; Eleftherios Giazitzoglou; Theodoros Zografos; Kenneth A Ellenbogen; A John Camm
Journal:  J Interv Card Electrophysiol       Date:  2010-12-14       Impact factor: 1.900

Review 2.  Atrial Fibrillation Ablation Using Magnetic Navigation Comparison With Conventional Approach During Long-Term Follow-Up.

Authors:  Tolga Aksu; Serdar Bozyel; Ebru Golcuk; Kývanc Yalin; Tumer Erdem Guler
Journal:  J Atr Fibrillation       Date:  2015-10-31

3.  Remotely controlled steerable sheath improves result and procedural parameters of atrial fibrillation ablation with magnetic navigation.

Authors:  Abdelkarim Errahmouni; Decebal Gabriel Latcu; Sok-Sithikun Bun; Nicolas Rijo; Céline Dugourd; Nadir Saoudi
Journal:  Europace       Date:  2015-02-05       Impact factor: 5.214

4.  A comparative analysis of clinical outcomes and disposable costs of different catheter ablation methods for the treatment of atrioventricular nodal reentrant tachycardia.

Authors:  Adam E Berman; Harold Rivner; Robin Chalkley; Vahé Heboyan
Journal:  Clinicoecon Outcomes Res       Date:  2017-11-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.