Literature DB >> 19893964

Reproducibility, reliability and validity of measurements obtained from Cecile3 digital models.

Gustavo Adolfo Watanabe-Kanno1, Jorge Abrão, Hiroshi Miasiro Junior, Alfonso Sánchez-Ayala, Manuel O Lagravère.   

Abstract

The aim of this study was to determine the reproducibility, reliability and validity of measurements in digital models compared to plaster models. Fifteen pairs of plaster models were obtained from orthodontic patients with permanent dentition before treatment. These were digitized to be evaluated with the program Cécile3 v2.554.2 beta. Two examiners measured three times the mesiodistal width of all the teeth present, intercanine, interpremolar and intermolar distances, overjet and overbite. The plaster models were measured using a digital vernier. The t-Student test for paired samples and interclass correlation coefficient (ICC) were used for statistical analysis. The ICC of the digital models were 0.84 +/- 0.15 (intra-examiner) and 0.80 +/- 0.19 (inter-examiner). The average mean difference of the digital models was 0.23 +/- 0.14 and 0.24 +/- 0.11 for each examiner, respectively. When the two types of measurements were compared, the values obtained from the digital models were lower than those obtained from the plaster models (p < 0.05), although the differences were considered clinically insignificant (differences < 0.1 mm). The Cécile digital models are a clinically acceptable alternative for use in Orthodontics.

Entities:  

Mesh:

Year:  2009        PMID: 19893964     DOI: 10.1590/s1806-83242009000300011

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  17 in total

1.  Comparison of clinical bracket point registration with 3D laser scanner and coordinate measuring machine.

Authors:  Mahtab Nouri; Arash Farzan; Ali Reza Akbarzadeh Baghban; Reza Massudi
Journal:  Dental Press J Orthod       Date:  2015 Jan-Feb

2.  Correlation and agreement of a digital and conventional method to measure arch parameters.

Authors:  Nes Nawi; Alizae Marny Mohamed; Murshida Marizan Nor; Nor Atika Ashar
Journal:  J Orofac Orthop       Date:  2017-11-07       Impact factor: 1.938

3.  Dimensional accuracy of jaw scans performed on alginate impressions or stone models: A practice-oriented study.

Authors:  Annike B Vogel; Fatih Kilic; Falko Schmidt; Sebastian Rübel; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

4.  Reliability of measurements made on scanned cast models using the 3 Shape R 700 scanner.

Authors:  L S Lemos; I M C R Rebello; C J Vogel; M C Barbosa
Journal:  Dentomaxillofac Radiol       Date:  2015-02-27       Impact factor: 2.419

5.  Reliability of Bolton analysis evaluation in tridimensional virtual models.

Authors:  Marianna Mendonca Brandão; Marcio Costal Sobral; Carlos Jorge Vogel
Journal:  Dental Press J Orthod       Date:  2015-10

Review 6.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

7.  Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography.

Authors:  Jooseong Kim; Giseon Heo; Manuel O Lagravère
Journal:  Angle Orthod       Date:  2013-08-19       Impact factor: 2.079

8.  A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction.

Authors:  Ji-Won Anh; Ji-Man Park; Youn-Sic Chun; Miae Kim; Minji Kim
Journal:  Korean J Orthod       Date:  2016-01-25       Impact factor: 1.372

9.  Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

Authors:  Jae-Hong Kim; Ki-Baek Kim; Woong-Chul Kim; Ji-Hwan Kim; Hae-Young Kim
Journal:  Korean J Orthod       Date:  2014-03-19       Impact factor: 1.372

10.  Dental measurements and Bolton index reliability and accuracy obtained from 2D digital, 3D segmented CBCT, and 3d intraoral laser scanner.

Authors:  Verónica San José; Carlos Bellot-Arcís; Beatriz Tarazona; Natalia Zamora; Manuel O Lagravère; Vanessa Paredes-Gallardo
Journal:  J Clin Exp Dent       Date:  2017-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.