Literature DB >> 19892585

CPOL: complex phase order likelihood as a similarity measure for MR-CT registration.

Alexander Wong1, David A Clausi, Paul Fieguth.   

Abstract

A novel similarity measure for registering magnetic resonance (MR) and computed tomography (CT) images has been designed and built. MR-CT registration methods often rely on the statistical intensity relationship between the images. The proposed similarity measure instead depends on the statistical relationship between the complex phase order between the images. By utilizing the complex phase order likelihood (CPOL) as a similarity measure, structural relationships instead of intensity relationships are explicitly used. This approach can be advantageous for MR-CT registration, where the intensities of the CT imagery have highly complex and nonlinear relationships with the intensities of corresponding MR imagery but simpler linear structural relationships. This new similarity measure has been tested on real MR-CT 3D volumes and has been evaluated based on fiducial registration error to determine alignment accuracy. Quantitative results show that CPOL is capable of achieving comparable alignment accuracy when compared to normalized mutual information, while being more robust to imaging artifacts such as noise.

Mesh:

Year:  2009        PMID: 19892585     DOI: 10.1016/j.media.2009.10.002

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  4 in total

1.  Multi-modal and multi-vendor retina image registration.

Authors:  Zhang Li; Fan Huang; Jiong Zhang; Behdad Dashtbozorg; Samaneh Abbasi-Sureshjani; Yue Sun; Xi Long; Qifeng Yu; Bart Ter Haar Romeny; Tao Tan
Journal:  Biomed Opt Express       Date:  2018-01-03       Impact factor: 3.732

2.  Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements.

Authors:  Alexander Wong; Chenyi Liu; Xiao Yu Wang; Paul Fieguth; Hongxia Bie
Journal:  BMC Med Imaging       Date:  2015-03-18       Impact factor: 1.930

3.  Abdominopelvic MR to CT registration using a synthetic CT intermediate.

Authors:  Jin Uk Heo; Feifei Zhou; Robert Jones; Jiamin Zheng; Xin Song; Pengjiang Qian; Atallah Baydoun; Melanie S Traughber; Jung-Wen Kuo; Rose Al Helo; Cheryl Thompson; Norbert Avril; Daniel DeVincent; Harold Hunt; Amit Gupta; Navid Faraji; Michael Z Kharouta; Arash Kardan; David Bitonte; Christian B Langmack; Aaron Nelson; Alexandria Kruzer; Min Yao; Jennifer Dorth; John Nakayama; Steven E Waggoner; Tithi Biswas; Eleanor Harris; Susan Sandstrom; Bryan J Traughber; Raymond F Muzic
Journal:  J Appl Clin Med Phys       Date:  2022-08-03       Impact factor: 2.243

4.  Monte Carlo-based noise compensation in coil intensity corrected endorectal MRI.

Authors:  Dorothy Lui; Amen Modhafar; Masoom A Haider; Alexander Wong
Journal:  BMC Med Imaging       Date:  2015-10-12       Impact factor: 1.930

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.