Literature DB >> 19892291

Predictable drill-free screw positioning with a graduated 3-dimensional radiographic-surgical guide: a preliminary report.

Sérgio Estelita1, Guilherme Janson, Kelly Chiqueto, Marcos Janson, Marcos Roberto de Freitas.   

Abstract

INTRODUCTION: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated.
METHODS: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS - 6-DFS)/2, which represents deviation of the mini-implant's final position regarding the central point initially selected. Then SW, ID, and screw diameter (SØ) were combined to estimate the surgical risk with RI expressed by RI = SØ/SW - ID.
RESULTS: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW.
CONCLUSIONS: The G-RSG accuracy allowed fine prediction of the final DFS position in the interradicular septum, with a low RI, which is a helpful tool to estimate surgical risks.

Entities:  

Mesh:

Year:  2009        PMID: 19892291     DOI: 10.1016/j.ajodo.2007.12.028

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  8 in total

1.  Accuracy of orthodontic miniscrew implantation guided by stereolithographic surgical stent based on cone-beam CT-derived 3D images.

Authors:  Lingling Qiu; Naoto Haruyama; Shoichi Suzuki; Daisuke Yamada; Naoto Obayashi; Toru Kurabayashi; Keiji Moriyama
Journal:  Angle Orthod       Date:  2011-08-17       Impact factor: 2.079

2.  Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

Authors:  Jae-Jung Yu; Gyu-Tae Kim; Yong-Suk Choi; Eui-Hwan Hwang; Janghyun Paek; Seong-Hun Kim; John C Huang
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

3.  Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review.

Authors:  Reint Meursinge Reynders; Luisa Ladu; Laura Ronchi; Nicola Di Girolamo; Jan de Lange; Nia Roberts; Annette Plüddemann
Journal:  Syst Rev       Date:  2015-04-02

4.  Evaluation of orthodontic mini-implant placement: a CBCT study.

Authors:  Shilpa Kalra; Tulika Tripathi; Priyank Rai; Anup Kanase
Journal:  Prog Orthod       Date:  2014-11-18       Impact factor: 2.750

5.  Clinical effectiveness of orthodontic miniscrew implantation guided by a novel cone beam CT image-based computer aided design and computer aided manufacturing (CAD-CAM) template.

Authors:  Lingling Qiu; Hui Xu; Pingping Feng; Xiaoyan Sha; Hongwei Zhang
Journal:  Ann Transl Med       Date:  2021-06

6.  The anatomical evaluation of the dental arches using cone beam computed tomography--an investigation of the availability of bone for placement of mini-screws.

Authors:  Feng Pan; Chung H Kau; Hong Zhou; Nada Souccar
Journal:  Head Face Med       Date:  2013-04-20       Impact factor: 2.151

Review 7.  Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review.

Authors:  Reint Meursinge Reynders; Luisa Ladu; Laura Ronchi; Nicola Di Girolamo; Jan de Lange; Nia Roberts; Annette Plüddemann
Journal:  Syst Rev       Date:  2016-03-31

8.  Additional intraoral radiographs may change the judgment regarding the final position of orthodontic mini-implants.

Authors:  Marina K Oba; Guido A Marañón-Vásquez; Fábio L Romano; Christiano Oliveira-Santos
Journal:  Dental Press J Orthod       Date:  2018 Mar-Apr
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.