Literature DB >> 19890564

Annual transition and seasonal variation of indoor air pollution levels of 2-ethyl-1-hexanol in large-scale buildings in Nagoya, Japan.

Kiyoshi Sakai1, Michihiro Kamijima, Eiji Shibata, Hiroyuki Ohno, Tamie Nakajima.   

Abstract

2-Ethyl-1-hexanol (2E1H) is a possible causative chemical for sick building symptoms; however, thus far, we do not have a clear understanding of the indoor air pollution levels caused by it. In this study, first, airborne 2E1H concentrations were measured during summer and winter from 2004 to 2007 in 67 rooms of 56 large-scale buildings in Nagoya, Japan, in order to show the seasonal variation of indoor air pollution levels of 2E1H. Then, a follow-up survey was conducted in five rooms of five buildings for more than 2 years in order to establish the annual transition of their 2E1H indoor air pollution levels. 2E1H was found to be one of the predominant volatile organic compounds in the indoor air of large-scale buildings. Its geometric mean concentration was significantly higher during summer (55.4 microg/m3) than during winter (13.7 microg/m3) (p < 0.01), although there was a significant difference in the concentrations among the buildings. High 2E1H concentrations may have been caused by high emission rates of 2E1H from floors, because of the hydrolysis of di(2-ethylhexyl) phthalate in polyvinyl chloride flooring materials or of adhesives containing 2-ethylhexyl moieties. Follow-up observations showed little decrease in the indoor air 2E1H concentrations from one year to the next, although they did show seasonal fluctuations, with an evident increase in concentrations during summer and an evident decrease during winter.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19890564     DOI: 10.1039/b910558a

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  4 in total

1.  Evaluation of a real-time method for monitoring volatile organic compounds in indoor air in a Japanese university.

Authors:  Hajime Hori; Sumiyo Ishimatsu; Yukiko Fueta; Toru Ishidao
Journal:  Environ Health Prev Med       Date:  2012-11-27       Impact factor: 3.674

Review 2.  Comprehensive review of 2-ethyl-1-hexanol as an indoor air pollutant.

Authors:  Takanari Wakayama; Yuki Ito; Kiyoshi Sakai; Mio Miyake; Eiji Shibata; Hiroyuki Ohno; Michihiro Kamijima
Journal:  J Occup Health       Date:  2019-01       Impact factor: 2.708

3.  Emissions of DEHP-free PVC flooring.

Authors:  Emmanuelle Castagnoli; Peter Backlund; Oskari Talvitie; Tapani Tuomi; Arja Valtanen; Raimo Mikkola; Hanna Hovi; Katri Leino; Jarek Kurnitski; Heidi Salonen
Journal:  Indoor Air       Date:  2019-09-11       Impact factor: 5.770

4.  Inhalation exposure to 2-ethyl-1-hexanol causes hepatomegaly and transient lipid accumulation without induction of peroxisome proliferator-activated receptor alpha in mice.

Authors:  Takanari Wakayama; Yuki Ito; Mio Miyake; Karin Nomasa; Kiyoshi Sakai; Naoko Oya; Hirotaka Sato; Hiroyuki Ohno; Michihiro Kamijima
Journal:  Ind Health       Date:  2021-09-28       Impact factor: 2.707