Literature DB >> 19890087

Microbial contamination of syringes during preparation: the direct influence of environmental cleanliness and risk manipulations on end-product quality.

Cyril Stucki1, Anna-Maria Sautter, Jocelyne Favet, Pascal Bonnabry.   

Abstract

PURPOSE: The direct influence of environmental cleanliness and risk manipulations on prepared syringes was evaluated.
METHODS: Media-fill testing was used to estimate potential microbial contamination. Syringes were prepared in three different environments using four different uncontrolled high-risk manipulations. The three environments included an International Organization for Standardization (ISO) class 5 horizontal laminar-airflow hood in an ISO class 6 cleanroom (in accordance with United States Pharmacopeia [USP] chapter 797), an ISO class 7 drug preparation area of an operating room, and an uncontrolled decentralized pharmacy in a ward. For each combination of environment and manipulation, 100 syringes were filled by a single operator. The four high-risk manipulations used included simple filling of syringes with trypticase soy broth, three-second contact by the ungloved fingers of the operator with the hub of the syringe, three-second contact between an object and the hub of the syringe, and exposure of the filled syringes to ambient air for 10 minutes.
RESULTS: Of the 1500 syringes prepared in three different environments, none produced within the cleanroom contained microorganisms, 6% were contaminated in the operating room, and 16% were contaminated in the ward (p < 0.0001). Certain high-risk manipulations were associated with a significant increase in the contamination of the surrogate syringes, including exposure to nonsterile ambient air and nonsterile objects or fingers (p < 0.0001).
CONCLUSION: High contamination rates were measured when the hub of syringes touched nonsterile environmental surfaces and fingers, whereas the drawn-air manipulation was associated with a lower risk of contamination. Working within a properly operating unidirectional airflow primary engineering control in an ISO class 5 cleanroom in accordance with USP chapter 797 requirements was demonstrated to be the best way to avoid bacterial or fungal contamination of injectable drugs directly resulting in patient infections.

Entities:  

Mesh:

Year:  2009        PMID: 19890087     DOI: 10.2146/ajhp070681

Source DB:  PubMed          Journal:  Am J Health Syst Pharm        ISSN: 1079-2082            Impact factor:   2.637


  16 in total

1.  Estimated cost savings from reducing errors in the preparation of sterile doses of medications.

Authors:  Terry F Urbine; Philip J Schneider
Journal:  Hosp Pharm       Date:  2014-09

2.  A Review of Scientific Literature of Interest to Office-Based Anesthesiology Practitioners.

Authors:  Mark A Saxen; Richard D Urman; Joseph T Homsi
Journal:  Anesth Prog       Date:  2019

3.  An outbreak of streptococcus endophthalmitis after intravitreal injection of bevacizumab.

Authors:  Roger A Goldberg; Harry W Flynn; Ryan F Isom; Darlene Miller; Serafin Gonzalez
Journal:  Am J Ophthalmol       Date:  2012-02       Impact factor: 5.258

4.  Streptococcus endophthalmitis outbreak after intravitreal injection of bevacizumab: one-year outcomes and investigative results.

Authors:  Roger A Goldberg; Harry W Flynn; Darlene Miller; Serafin Gonzalez; Ryan F Isom
Journal:  Ophthalmology       Date:  2013-02-28       Impact factor: 12.079

Review 5.  A systematic review and meta-analysis of microbial contamination of parenteral medication prepared in a clinical versus pharmacy environment.

Authors:  Karin H M Larmené-Beld; Henderik W Frijlink; Katja Taxis
Journal:  Eur J Clin Pharmacol       Date:  2019-01-25       Impact factor: 2.953

6.  Comparison of Aseptic Compounding Errors Before and After Modified Laboratory and Introductory Pharmacy Practice Experiences.

Authors:  Vincent C Dennis; Arthur H Owora; Alice E Kirkpatrick
Journal:  Am J Pharm Educ       Date:  2015-12-25       Impact factor: 2.047

7.  Incorrect aseptic techniques in medicine preparation and recommendations for safer practices: a systematic review.

Authors:  Eeva Suvikas-Peltonen; Suvi Hakoinen; Ercan Celikkayalar; Raisa Laaksonen; Marja Airaksinen
Journal:  Eur J Hosp Pharm       Date:  2016-10-12

Review 8.  Review of studies examining microbial contamination of vials used for preparations done with closed-system drug transfer devices.

Authors:  Annaelle Soubieux; Cynthia Tanguay; Jean-François Bussières
Journal:  Eur J Hosp Pharm       Date:  2019-05-15

9.  Pumping infusions with a syringe may cause contamination of the fluid in the syringe.

Authors:  Yutaka Kawakami; Takashi Tagami
Journal:  Sci Rep       Date:  2021-07-29       Impact factor: 4.379

10.  Impact of a modified Broviac maintenance care bundle on bloodstream infections in paediatric cancer patients.

Authors:  Rhoikos Furtwängler; Carolin Laux; Norbert Graf; Arne Simon
Journal:  GMS Hyg Infect Control       Date:  2015-11-16
View more