The effect of bipole tip-to-ring distance in atrial electrodes upon atrial tachyarrhythmia sensing capability in modern dual-chamber pacemakers.

John Silberbauer1, Anita Arya, Rick A Veasey, Lana Boodhoo, Kayvan Kamalvand, Sean O'Nunain, David Hildick-Smith, Vince Paul, Nikhil R Patel, Guy W Lloyd, Neil Sulke.   

Abstract

INTRODUCTION: Accurate atrial arrhythmia discrimination is important for dual chamber pacemakers and defibrillators. The aim was to assess the accuracy of atrial arrhythmia recording using modern devices and relate this to atrial tip-to-ring (TTR) distance.
METHODS: One hundred eighty-two patients (72 + or - 9 years, 55% male) with paroxysmal atrial fibrillation were enrolled and were included in the study if they had an atrial fibrillation (AF) burden of 1-50% during a monitoring phase. Seventy-nine patients fulfilled these criteria and were followed for at least 5 months. Electrodes were classified as having short (<10 mm), medium (10-12), or long (13-18) atrial TTR spacing.
RESULTS: Two thousand eight hundred eighty-three detailed onset reports were analyzed; 730 (25%) demonstrated aberrant sensing. Six percent were due to farfield R wave oversensing (FFRWO) and 19% due to undersensing, sometimes occurring in the same patient and study phase. FFRWO was significantly reduced with short TTR electrodes (P < 0.05). Undersensing due to sensitivity fallout was 18% (short), 24% (medium), and 17% (long) (P = ns). Undersensing due to pacemaker blanking was 11% (short), 11% (medium), and 12% (long) (P = ns). Active fixation electrodes did not show any difference from passive fixation.
CONCLUSION: Atrial electrodes with a short TTR (<10 mm) significantly reduce FFRWO without increasing undersensing and should be used routinely in patients with paroxysmal atrial tachyarrhythmias. However, 20% of atrial tachyarrythmia episodes were incorrectly classified as terminated by these modern devices due to undersensing. Clinicians should be wary of using device-derived endpoints that rely on AF episode number or duration as these may be falsely increased or reduced, respectively.

Entities:  

Mesh:

Year:  2009        PMID: 19889192     DOI: 10.1111/j.1540-8159.2009.02576.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  The natural history of atrial fibrillation in patients with permanent pacemakers: is atrial fibrillation a progressive disease?

Authors:  R A Veasey; C Sugihara; K Sandhu; G Dhillon; N Freemantle; S S Furniss; A N Sulke
Journal:  J Interv Card Electrophysiol       Date:  2015-07-03       Impact factor: 1.900

2.  Use of an atrial lead with very short tip-to-ring spacing avoids oversensing of far-field R-wave.

Authors:  Christof Kolb; Georg Nölker; Carsten Lennerz; Hansmartin Jetter; Verena Semmler; Klaus Pürner; Klaus-Jürgen Gutleben; Tilko Reents; Klaus Lang; Ulrich Lotze
Journal:  PLoS One       Date:  2012-06-22       Impact factor: 3.240

3.  Enhanced detection of atrial tachyarrhythmias with pacing devices by using more accurate atrial sensing.

Authors:  Sami Pakarinen; Mika Lehto; Jaap Ruiter; Willem G de Voogt
Journal:  J Interv Card Electrophysiol       Date:  2021-10-01       Impact factor: 1.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.