Literature DB >> 19889057

MRSA screening: can one swab be used for both culture and rapid testing? An evaluation of chromogenic culture and subsequent Hain GenoQuick PCR amplification/detection.

O Sherlock1, A Dolan, H Humphreys.   

Abstract

The use of a single swab for both MRSA culture and for rapid testing by PCR was evaluated, using the Hain GenoQuick (GQM) methicillin resistant Staphylococcus aureus (MRSA) assay for the rapid detection of MRSA, as a single swab would be the preferred option for routine diagnostic testing. GQM detected current prevalent Irish MRSA strains incorporating all known SSCmec types, including Panton-Valentine leukocidin-positive strains. Using the GQM method, all methicillin-resistant coagulase-negative staphylococci tested were confirmed to be negative, although three of seven gentamicin-resistant methicillin-sensitive Staphylococcus aureus strains tested were identified as MRSA. The theoretical ex-vivo limit of detection of the assay was 704 CFU per GQM assay reaction (1.7 × 10(4) CFU/mL) when MRSA suspensions were used for DNA extraction, or 1.4 × 10(3) CFU/swab (1.4 × 10(4) CFU/mL) using MRSA absorbed onto Copan screening swabs. Swab processing on chromogenic agar prior to PCR resulted in some inhibition of the PCR reaction, increasing the limit of detection of the assay by a factor of four. Based on 540 single swab screening specimens (nasal and groin) processed first for culture assay, then by GQM, the specificity and positive predictive value were both 100%, the negative predictive value was 92%, and the sensitivity was 57%. Culture followed by PCR from a single specimen is not optimal for the rapid detection of MRSA. Further laboratory validation of the GQM assay is required to determine the true diagnostic sensitivity and value of this kit in routine microbiology laboratories, modifying the protocol for single specimens, or using two specimens.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19889057     DOI: 10.1111/j.1469-0691.2009.02948.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  3 in total

1.  Direct detection of Mycobacterium tuberculosis complex in clinical samples by a molecular method based on GenoQuick technology.

Authors:  Raquel Moure; Miriam Torres; Rogelio Martín; Fernando Alcaide
Journal:  J Clin Microbiol       Date:  2012-03-14       Impact factor: 5.948

2.  Characterization of Staphylococcus aureus isolates with a partial or complete absence of staphylococcal cassette chromosome elements.

Authors:  Henry Wong; Lisa Louie; Reggie Y C Lo; Andrew E Simor
Journal:  J Clin Microbiol       Date:  2010-07-28       Impact factor: 5.948

3.  Comparative assessment of methicillin resistant Staphylococcus aureus diagnostic assays for use in resource-limited settings.

Authors:  A Ayebare; L M Bebell; J Bazira; S Ttendo; V Katawera; D R Bangsberg; M J Siedner; P G Firth; Y Boum Ii
Journal:  BMC Microbiol       Date:  2019-08-22       Impact factor: 4.465

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.