Could the colonic capsule PillCam Colon be clinically useful for selecting patients who deserve a complete colonoscopy?: results of clinical comparison with colonoscopy in the perspective of colorectal cancer screening.

Gerard Gay1, Michel Delvaux, Muriel Frederic, Isaac Fassler.   

Abstract

OBJECTIVES: Preliminary studies have shown the possibility of detecting colonic polyps and tumors using the PillCam Colon capsule endoscope (CCE) (Given Imaging, Yoqneam, Israel). The aim of this study was to evaluate the ability of CCE to detect clinically relevant colonic findings as compared with colonoscopy, and further, to test the assumption that CCE used in the frame of colorectal cancer (CRC) screening could accurately discriminate patients deserving a complete colonoscopy.
METHODS: A total of 128 patients (67 men, 55+/-14 years) with an indication of colonoscopy were investigated by CCE, followed by colonoscopy under general anesthesia on the next day. Bowel cleansing was carried out according to a previously published protocol (3 l polyethylene glycol+2 doses of sodium phosphate solution). All CCE recordings were read by the same physician and all colonoscopies, performed by the same operator, were blinded to each other's results. The primary outcome of the study was the decision made by the CCE reader to indicate a colonoscopy, compared with the final result of the colonoscopy. Secondary outcomes were the agreement between CCE and colonoscopy for making a diagnosis of colorectal disease, as well as detection rate, number, and size of polyps.
RESULTS: Two patients were excluded: one did not swallow the capsule and the other was diagnosed with a jejunal stenosis by the CCE. The CCE found at least one clinically relevant colonic finding in 71 patients (56.3%), and the colonoscopy results confirmed this finding in 56 patients, showing a sensitivity of CCE of 87.5% (confidence interval (CI) 79.4-95.6%) and a specificity of 75.8% (CI 65.4-86.2%). With a prevalence of 50.8% of clinically relevant findings at colonoscopy, the positive predictive value of CCE was 78.9%, and the negative predictive value (NPV) was 85.4%. The agreement between CCE and colonoscopy was significant for the detection of any colonic lesion (P<0.0001), polyps (P<0.001), as well as for the detection of the number (P<0.0001) and size (P=0.0083) of polyps. Tolerance of the procedure was excellent, and no complication was reported.
CONCLUSIONS: In the setting of this study, CCE seemed to be effective in detecting clinically significant colonic findings in patients with an indication of colonoscopy. The high NPV and excellent tolerance of CCE suggest that it could be evaluated in large CRC-screening programs and further studies in screening conditions should also evaluate its cost-efficacy ratio.

Entities:  

Mesh:

Year:  2009        PMID: 19888198     DOI: 10.1038/ajg.2009.624

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  15 in total

1.  Colon capsule endoscopy: Advantages, limitations and expectations. Which novelties?

Authors:  Maria Elena Riccioni; Riccardo Urgesi; Rossella Cianci; Alessandra Bizzotto; Cristiano Spada; Guido Costamagna
Journal:  World J Gastrointest Endosc       Date:  2012-04-16

Review 2.  Colon capsule endoscopy: toward the future.

Authors:  Naoki Muguruma; Kumiko Tanaka; Satoshi Teramae; Tetsuji Takayama
Journal:  Clin J Gastroenterol       Date:  2017-01-13

Review 3.  Colon capsule endoscopy: current status and future directions.

Authors:  Andrea O Tal; Johannes Vermehren; Jörg G Albert
Journal:  World J Gastroenterol       Date:  2014-11-28       Impact factor: 5.742

4.  First Pillcam Colon 2 capsule images of Whipple's disease: Case report and review of the literature.

Authors:  Bogdan Radu Mateescu; Andreea Bengus; Madalina Marinescu; Florica Staniceanu; Gianina Micu; Lucian Negreanu
Journal:  World J Gastrointest Endosc       Date:  2012-12-16

5.  Feasibility of a novel low-volume and sodium phosphate-free bowel preparation regimen for colon capsule endoscopy.

Authors:  Jieqiong Zhou; Xiaowei Tang; Jing Wang; Zhenyu Chen; Xinying Wang; Bo Jiang
Journal:  Exp Ther Med       Date:  2017-06-23       Impact factor: 2.447

Review 6.  Is there a role for colon capsule endoscopy beyond colorectal cancer screening? A literature review.

Authors:  Konstantinos Triantafyllou; Iosif Beintaris; George D Dimitriadis
Journal:  World J Gastroenterol       Date:  2014-09-28       Impact factor: 5.742

Review 7.  Bowel preparation regimens for colon capsule endoscopy: a review.

Authors:  Shashideep Singhal; Sofia Nigar; Vani Paleti; Devin Lane; Sushil Duddempudi
Journal:  Therap Adv Gastroenterol       Date:  2014-05       Impact factor: 4.409

8.  Capsule endoscopy compared with conventional colonoscopy for detection of colorectal neoplasms.

Authors:  Andreas Sieg
Journal:  World J Gastrointest Endosc       Date:  2011-05-16

9.  New reduced volume preparation regimen in colon capsule endoscopy.

Authors:  Yasuo Kakugawa; Yutaka Saito; Shoichi Saito; Kenji Watanabe; Naoki Ohmiya; Mitsuyuki Murano; Shiro Oka; Tetsuo Arakawa; Hidemi Goto; Kazuhide Higuchi; Shinji Tanaka; Hideki Ishikawa; Hisao Tajiri
Journal:  World J Gastroenterol       Date:  2012-05-07       Impact factor: 5.742

Review 10.  Applications of Colon Capsule Endoscopy.

Authors:  Shabana F Pasha
Journal:  Curr Gastroenterol Rep       Date:  2018-04-12