Literature DB >> 19885184

The next generation of artificial pancreas control algorithms.

Rodrigo E Teixeira1, Stephen Malin.   

Abstract

Creating a wearable artificial pancreas (AP) by closing the loop between a glucose sensor and an insulin infusion pump has the potential to significantly impact the complications associated with and improve the quality of life of diabetic individuals. Despite recent progress on glucose sensor and insulin infusion technologies, control algorithms built on the simple glucose value efferent and insulin dose afferent model are not efficient and reliable. Based on glucose regulatory mechanisms known to date, their impairment in the diabetic state, and fundamental principles of control theory, some corrections to the present course of research are proposed to facilitate the removal of this barrier. A greater emphasis on model predictive controllers or controllers that exploit a mathematical representation, or model, of the patient's own physiology is proposed. Whole-body physiologically based pharmacokinetics-pharmacodynamics-type models hold the best odds for enabling a successful closed-loop AP. However, two major improvements to the diabetes modeling state of the art are required to make them practical for daily care: integrating hypothalamus-pituitary-adrenal axis and gastrointestinal tract submodels. Although there are simple representations of these in current existence, large concerted efforts between experimentalists and modelers will be required to enhance their accuracy. Finally, changes in hardware that complements controller performance are suggested. For instance, the development of dual control inputs of insulin and glucagon could relax tolerances on controller accuracy.

Entities:  

Keywords:  artificial pancreas; control; diabetes; glucagon; meal; model; stress

Year:  2008        PMID: 19885184      PMCID: PMC2769707          DOI: 10.1177/193229680800200115

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  39 in total

Review 1.  Continuous glucose monitoring and closed-loop systems.

Authors:  R Hovorka
Journal:  Diabet Med       Date:  2006-01       Impact factor: 4.359

Review 2.  Minimal model: perspective from 2005.

Authors:  Richard N Bergman
Journal:  Horm Res       Date:  2006-01-20

Review 3.  Roles of circadian rhythmicity and sleep in human glucose regulation.

Authors:  E Van Cauter; K S Polonsky; A J Scheen
Journal:  Endocr Rev       Date:  1997-10       Impact factor: 19.871

4.  A mathematical model for the control mechanism of free fatty acid-glucose metabolism in normal humans.

Authors:  R Srinivasan; A H Kadish; R Sridhar
Journal:  Comput Biomed Res       Date:  1970-04

5.  Open loop control of multiple drug effects in anesthesia.

Authors:  D R Wada; D S Ward
Journal:  IEEE Trans Biomed Eng       Date:  1995-07       Impact factor: 4.538

6.  Inverse relation between amylin and glucagon secretion in healthy and diabetic human subjects.

Authors:  B Ludvik; K Thomaseth; J J Nolan; M Clodi; R Prager; G Pacini
Journal:  Eur J Clin Invest       Date:  2003-04       Impact factor: 4.686

7.  GIM, simulation software of meal glucose-insulin model.

Authors:  Chiara Dalla Man; Davide M Raimondo; Robert A Rizza; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-05

8.  Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. Diabetes Control and Complications Trial Research Group.

Authors: 
Journal:  J Pediatr       Date:  1994-08       Impact factor: 4.406

Review 9.  Gut peptides in the treatment of diabetes mellitus.

Authors:  Torsten P Vahl; David A D'Alessio
Journal:  Expert Opin Investig Drugs       Date:  2004-03       Impact factor: 6.206

Review 10.  Hypoglycemia as a barrier to glycemic control.

Authors:  Stephen Davis; Miriam D Alonso
Journal:  J Diabetes Complications       Date:  2004 Jan-Feb       Impact factor: 2.852

View more
  3 in total

1.  Personalized medicine for diabetes.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2008-05

Review 2.  Wearable and implantable pancreas substitutes.

Authors:  Leonardo Ricotti; Tareq Assaf; Paolo Dario; Arianna Menciassi
Journal:  J Artif Organs       Date:  2012-09-20       Impact factor: 1.731

3.  Systematically in silico comparison of unihormonal and bihormonal artificial pancreas systems.

Authors:  Xiaoteng Gao; Huangjiang Ning; Youqing Wang
Journal:  Comput Math Methods Med       Date:  2013-10-24       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.