Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy.

William L Clarke1, Boris Kovatchev.   

Abstract

Continuous glucose sensors (CGS) offer the potential to greatly change the lives of people with diabetes. Even though two of these systems (Guardian RT, Medtronic, Northridge, CA, and DexCom STS, DexCom, San Diego, CA) have been approved by the Food and Drug Administration for use as adjuncts to self-blood glucose monitoring (SBGM), questions remain concerning the accuracy of these devices. When considering accuracy, two distinct approaches should be emphasized: (1) numerical and (2) clinical. Because CGS data are a process in time, each of these two approaches includes two subtypes of accuracy: point and rate. Conventional statistics such as correlation coefficients, mean and median relative absolute differences, and International Standards Organization criteria are measures of numerical point accuracy. A new measure, the R deviation, is introduced to quantify numerical rate accuracy. Error-grid analysis (Clarke EGA) measures clinical point accuracy. The only measure of both clinical point accuracy and rate accuracy is continuous glucose error-grid analysis. This analysis is a combination of two components, P-EGA measuring point accuracy and R-EGA measuring rate accuracy, which are designed to assess the information that distinguishes continuous glucose measurements from intermittent SBGM determinations. Further, a better understanding of the source of the error associated with time lag and its effect on CGS readings may improve sensor output. Finally, the reliability of the CGS sensors, in terms of initial calibration and long-term application, needs to be assessed carefully if current CGS systems are to be used as hypoglycemia monitors or incorporated in the future design of closed loop (artificial pancreas) systems.

Entities:  

Keywords:  accuracy assessment; continuous glucose error grid analysis; continuous glucose monitoring

Year:  2007        PMID: 19885134      PMCID: PMC2769659          DOI: 10.1177/193229680700100510

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  21 in total

Review 1.  Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy.

Authors:  Eric Renard
Journal:  Curr Opin Pharmacol       Date:  2002-12       Impact factor: 5.547

Review 2.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

3.  Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring.

Authors:  Dorothee Deiss; Jan Bolinder; Jean-Pierre Riveline; Tadej Battelino; Emanuele Bosi; Nadia Tubiana-Rufi; David Kerr; Moshe Phillip
Journal:  Diabetes Care       Date:  2006-12       Impact factor: 19.112

4.  Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.

Authors:  Richard L Weinstein; Sherwyn L Schwartz; Ronald L Brazg; Jolyon R Bugler; Thomas A Peyser; Geoffrey V McGarraugh
Journal:  Diabetes Care       Date:  2007-03-02       Impact factor: 19.112

5.  Nocturnal hypoglycemia detected with the Continuous Glucose Monitoring System in pediatric patients with type 1 diabetes.

Authors:  Francine Ratner Kaufman; Juliana Austin; Aaron Neinstein; Lily Jeng; Mary Halvorson; Debra J Devoe; Pisit Pitukcheewanont
Journal:  J Pediatr       Date:  2002-11       Impact factor: 4.406

6.  Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.

Authors:  William L Clarke; Stacey Anderson; Leon Farhy; Marc Breton; Linda Gonder-Frederick; Daniel Cox; Boris Kovatchev
Journal:  Diabetes Care       Date:  2005-10       Impact factor: 19.112

7.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

8.  Feasibility of automating insulin delivery for the treatment of type 1 diabetes.

Authors:  Garry M Steil; Kerstin Rebrin; Christine Darwin; Farzam Hariri; Mohammed F Saad
Journal:  Diabetes       Date:  2006-12       Impact factor: 9.461

9.  The accuracy of the CGMS in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy study.

Authors: 
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

10.  Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp.

Authors:  Christopher King; Stacey M Anderson; Marc Breton; William L Clarke; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2007-05
View more
  30 in total

1.  Evaluating the clinical accuracy of GlucoMen®Day: a novel microdialysis-based continuous glucose monitor.

Authors:  Francesco Valgimigli; Fausto Lucarelli; Cosimo Scuffi; Sara Morandi; Iolanda Sposato
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

2.  Real-time glucose estimation algorithm for continuous glucose monitoring using autoregressive models.

Authors:  Yenny Leal; Winston Garcia-Gabin; Jorge Bondia; Eduardo Esteve; Wifredo Ricart; Jose-Manuel Fernández-Real; Josep Vehí
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

Review 3.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

4.  Continuous glucose monitoring in subjects with type 1 diabetes: improvement in accuracy by correcting for background current.

Authors:  Joseph El Youssef; Jessica R Castle; Julia M Engle; Ryan G Massoud; W Kenneth Ward
Journal:  Diabetes Technol Ther       Date:  2010-09-30       Impact factor: 6.118

5.  Comparison of the numerical and clinical accuracy of four continuous glucose monitors.

Authors:  Boris Kovatchev; Stacey Anderson; Lutz Heinemann; William Clarke
Journal:  Diabetes Care       Date:  2008-03-13       Impact factor: 19.112

6.  Statistical tools to analyze continuous glucose monitor data.

Authors:  William Clarke; Boris Kovatchev
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

7.  Characterization of porous, dexamethasone-releasing polyurethane coatings for glucose sensors.

Authors:  Suzana G Vallejo-Heligon; Bruce Klitzman; William M Reichert
Journal:  Acta Biomater       Date:  2014-07-25       Impact factor: 8.947

8.  The correlation of hemoglobin A1c to blood glucose.

Authors:  Ken Sikaris
Journal:  J Diabetes Sci Technol       Date:  2009-05-01

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes.

Authors:  Boris P Kovatchev; Marc Breton; Chiara Dalla Man; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.