Literature DB >> 19884129

Implementation of device therapy (cardiac resynchronization therapy and implantable cardioverter defibrillator) for patients with heart failure in Europe: changes from 2004 to 2008.

Dirk J van Veldhuisen1, Alexander H Maass, Silvia G Priori, Pelle Stolt, Isabelle C van Gelder, Kenneth Dickstein, Karl Swedberg.   

Abstract

AIMS: Heart failure (HF) patients increasingly receive device therapy, either an implantable cardioverter defibrillator (ICD) or a biventricular pacemaker, also called cardiac resynchronization therapy (CRT), or a CRT device with an ICD (CRT-D). However, epidemiological data on the use of device therapy in Europe are limited. METHODS AND
RESULTS: Data on implantation rates for conventional pacemakers, ICD, CRT, and CRT-D in 15 Western European countries were obtained from the Eucomed Registry for the 5-year period 2004-2008. Implantation of conventional pacemakers increased by 9% in Europe over the 5 years (reaching 907/million in 2008) and there were significant differences between countries. Implantable cardioverter defibrillator implantations increased by 75% from 80/million in 2004 to 140/million in 2008, and differences between countries were larger than those for conventional pacemakers. Implantation rates for CRT-P alone increased slightly from 2004 to 2006, but remained at 25/million thereafter in Europe overall. The total number of CRT implants (CRT-P and -D) markedly increased from 46/million in 2004 to 99/million in 2008 (115%), but this was mainly due to more CRT-D implants, i.e. an increase in the proportion of CRT-D (from 55% in 2004 to 75% in 2008). Implantation rates for ICD, CRT, and CRT-D remained markedly different throughout the study period between countries.
CONCLUSION: Implantation rates of devices for HF, in particular ICD and CRT-D, have increased significantly between 2004 and 2008 in Europe, but there remain major differences between countries.

Entities:  

Mesh:

Year:  2009        PMID: 19884129     DOI: 10.1093/eurjhf/hfp149

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  27 in total

Review 1.  Effectiveness of cardiac resynchronization therapy in mild congestive heart failure: systematic review and meta-analysis of randomized trials.

Authors:  Steven A Lubitz; Peter Leong-Sit; Nowell Fine; Daniel B Kramer; Jagmeet Singh; Patrick T Ellinor
Journal:  Eur J Heart Fail       Date:  2010-04       Impact factor: 15.534

2.  Phantom shocks: innocent bystander or complication of implantable cardioverter defibrillator therapy?

Authors:  A H Maass
Journal:  Neth Heart J       Date:  2013-04       Impact factor: 2.380

3.  Long-term incidence of inappropriate shocks in patients with implantable cardioverter defibrillators in clinical practice-an underestimated complication?

Authors:  Daniel Hofer; Jan Steffel; David Hürlimann; Laurent Haegeli; Thomas F Lüscher; Firat Duru; Urs Eriksson; Nazmi Krasniqi
Journal:  J Interv Card Electrophysiol       Date:  2017-11-25       Impact factor: 1.900

4.  Complex cardiac pacing in the setting of a district general hospital: procedural success and complications.

Authors:  Hazim Rahbi; Mohammed El-Din; Mohammad Salloum; Naeem Shaukat; Mohsin Farooq
Journal:  Heart Asia       Date:  2014-06-24

5.  [Inappropriate ICD therapies: All problems solved with MADIT-RIT?].

Authors:  Christof Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-04-21

6.  Changing nature of cardiac interventions in older adults.

Authors:  John A Dodson; Mathew S Maurer
Journal:  Aging health       Date:  2011-04

7.  Comparing outcome of patients with coronary artery disease and dilated cardiomyopathy in ICD and CRT recipients: data from the German DEVICE-registry.

Authors:  Kristina Wasmer; Julia Köbe; Dietrich Andresen; Ralf Zahn; Stefan G Spitzer; Joachim Jehle; Johannes Brachmann; Christoph Stellbrink; Eimo Martens; Matthias Hochadel; Jochen Senges; Helmut Klein; Lars Eckardt
Journal:  Clin Res Cardiol       Date:  2013-03-30       Impact factor: 5.460

8.  [Current clinical practise of cardiac resynchronisation therapy in Austria--national results from the European CRT Survey].

Authors:  Wolfgang Dichtl; Bernhard Strohmer; Friedrich Fruhwald
Journal:  Wien Klin Wochenschr       Date:  2011-02-28       Impact factor: 1.704

9.  Utilization and in-hospital complications of cardiac resynchronization therapy: trends in the United States from 2003 to 2013.

Authors:  Seyed Mohammadreza Hosseini; Kasra Moazzami; Guy Rozen; Jeena Vaid; Ahmed Saleh; Kevin E Heist; Mark Vangel; Jeremy N Ruskin
Journal:  Eur Heart J       Date:  2017-07-14       Impact factor: 29.983

10.  Mobile thrombus on cardiac implantable electronic device leads of patients undergoing cardiac ablation: incidence, management, and outcomes.

Authors:  Alan Sugrue; Christopher V DeSimone; Charles J Lenz; Douglas L Packer; Samuel J Asirvatham
Journal:  J Interv Card Electrophysiol       Date:  2015-12-09       Impact factor: 1.900

View more