Literature DB >> 19884000

E. coli outer membrane with autodisplayed Z-domain as a molecular recognition layer of SPR biosensor.

Joachim Jose1, Min Park, Jae-Chul Pyun.   

Abstract

In this work, the Z-domain of protein A was expressed as a recombinant-fusion protein on the outer membrane of Escherichia coli by using "Autodisplay" technology, and the outer membrane with Z-domains was layered on a SPR biosensor as a highly sensitive molecular recognition layer. The outer membrane layer formation was demonstrated by using various surfaces with controlled hydrophobicity. The effect of orientation control by the outer membrane with Z-domains was estimated to have far higher sensitivity and far improved limit of detection (LOD) in comparison to the conventional immunoassay by using a model analyte, horseradish peroxidase (HRP). The SPR biosensor with the outer membrane layer was applied to the detection of C-reactive protein (CRP). From these experiments, the LOD of SPR biosensor was estimated to improve more than 100-fold compared to the SPR biosensor with the antibody-layer by physical adsorption. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19884000     DOI: 10.1016/j.bios.2009.09.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Cell surface display of a β-glucosidase employing the type V secretion system on ethanologenic Escherichia coli for the fermentation of cellobiose to ethanol.

Authors:  Iván Muñoz-Gutiérrez; Ricardo Oropeza; Guillermo Gosset; Alfredo Martinez
Journal:  J Ind Microbiol Biotechnol       Date:  2012-05-26       Impact factor: 3.346

2.  A Regenerative Immunoaffinity Layer Based on the Outer Membrane of Z-Domains Autodisplaying E. coli for Immunoassays and Immunosensors.

Authors:  Daseul Jeon; Jae-Chul Pyun; Joachim Jose; Min Park
Journal:  Sensors (Basel)       Date:  2018-11-19       Impact factor: 3.576

Review 3.  Surface Display Technology for Biosensor Applications: A Review.

Authors:  Min Park
Journal:  Sensors (Basel)       Date:  2020-05-13       Impact factor: 3.576

Review 4.  Biosensors Based on Mechanical and Electrical Detection Techniques.

Authors:  Thomas Chalklen; Qingshen Jing; Sohini Kar-Narayan
Journal:  Sensors (Basel)       Date:  2020-09-30       Impact factor: 3.576

5.  Rapid and Highly Sensitive Detection of C-Reaction Protein Using Robust Self-Compensated Guided-Mode Resonance BioSensing System for Point-of-Care Applications.

Authors:  Chu-Tung Yeh; Devesh Barshilia; Chia-Jui Hsieh; Hsun-Yuan Li; Wen-Hsin Hsieh; Guo-En Chang
Journal:  Biosensors (Basel)       Date:  2021-12-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.