Literature DB >> 19883915

Optimizing the tissue anchoring performance of barbed sutures in skin and tendon tissues.

N P Ingle1, M W King.   

Abstract

The focus of the current work was to study how the geometric design of a single barbed monofilament suture effects its biomechanical behavior. Different cut angles and cut depths of barbs were prepared and tested in vitro for their tensile and tissue anchoring properties by means of a novel suture/tissue pullout test. Experiments were also performed using bovine tendon and porcine skin tissues. The experimental results revealed that since tendon tissue has a higher modulus than skin it needs a more rigid barb to penetrate and anchor the surrounding tissue. A cut angle of 150 degrees and a cut depth of 0.18 mm are therefore recommended. On the other hand, for the softer skin tissue, a cut angle of 170 degrees and a cut depth of 0.18 mm provides a more flexible barb that gives superior skin tissue anchoring. These findings confirm that the future development of barbed suture technology requires a detailed understanding of the biomechanical properties of the tissue in which they are to be used. This will lead to the future development of a range of tissue-specific barbed sutures. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19883915     DOI: 10.1016/j.jbiomech.2009.08.033

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

Review 1.  Prospective evaluation of unidirectional barbed suture for various indications in surgeon-controlled robotic reconstructive urologic surgery: Wake Forest University experience.

Authors:  Hemendra N Shah; Rishi Nayyar; Shrinivas Rajamahanty; Ashok K Hemal
Journal:  Int Urol Nephrol       Date:  2011-11-06       Impact factor: 2.370

Review 2.  Barbed Sutures and Tendon Repair-a Review.

Authors:  Ajul Shah; Megan Rowlands; Alexander Au
Journal:  Hand (N Y)       Date:  2015-03

3.  The resurgence of barbed suture and connecting devices for use in flexor tendon tenorrhaphy.

Authors:  Yazeed Mazen Gussous; Chunfeng Zhao; Peter C Amadio; Kai-Nan An
Journal:  Hand (N Y)       Date:  2011-06-30

4.  3D Printed Anchoring Sutures for Permanent Shaping of Tissues.

Authors:  Wei Wei; Yuxiao Li; Huazhe Yang; Reza Nassab; Fatemeh Shahriyari; Ali Akpek; Xiaofei Guan; Yanhui Liu; Shahrouz Taranejoo; Ali Tamayol; Yu Shrike Zhang; Ali Khademhosseini; Hae Lin Jang
Journal:  Macromol Biosci       Date:  2017-11-16       Impact factor: 4.979

5.  Comparison of surgical time and complication rate of subcutaneous and skin closure using barbed suture or traditional knotted suture in dogs.

Authors:  Laura K Nutt; Megan L Wilson; Sherisse Sakals
Journal:  Can Vet J       Date:  2017-12       Impact factor: 1.008

6.  Comparison of the mechanical properties and anchoring performance of polyvinylidene fluoride and polypropylene barbed sutures for tendon repair.

Authors:  Yihan Huang; Edwin R Cadet; Martin W King; Jacqueline H Cole
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2022-06-08       Impact factor: 3.405

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.