Literature DB >> 19883224

No evidence for a different RBE between pulsed and continuous 20 MeV protons.

T E Schmid1, G Dollinger, A Hauptner, V Hable, C Greubel, S Auer, A A Friedl, M Molls, B Röper.   

Abstract

To obtain greater insight into the future potential of tumor radiotherapy using proton beams generated from high-intensity lasers, it is important to characterize the ionization quality of the new beams by measuring the relative biological effectiveness (RBE) under conditions where the full dose at one irradiation site will be deposited by a few proton pulses less than 1 ns in duration. HeLa cells attached to a Mylar foil were irradiated with 70 kV X rays to obtain a reference dose-response curve or with 3 Gy of 20 MeV protons at the Munich tandem accelerator (Garching), either using a continuous mode where a cell sample was irradiated within a 100-ms time span or using a pulsed mode where radiation was given in a single proton pulse of about 1 ns. After irradiation cytochalasin B was added; 24 h later cells were fixed and stained with acridine orange and micronuclei were counted. The X-ray dose-response curve for the production of micronuclei in HeLa cells followed a linear-quadratic model. The corresponding RBE values for 20 MeV protons in pulsed and continuous irradiation modes were 1.07 +/- 0.08 and 1.06 +/- 0.10 in the first proton experiment and 1.09 +/- 0.08 and 1.05 +/- 0.11 in the second, respectively. There was no evidence for a difference in the RBE for pulsed and continuous irradiation of HeLa cells with 20 MeV protons.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19883224     DOI: 10.1667/RR1539.1

Source DB:  PubMed          Journal:  Radiat Res        ISSN: 0033-7587            Impact factor:   2.841


  15 in total

1.  Induction and repair of DNA double-strand breaks assessed by gamma-H2AX foci after irradiation with pulsed or continuous proton beams.

Authors:  O Zlobinskaya; G Dollinger; D Michalski; V Hable; C Greubel; G Du; G Multhoff; B Röper; M Molls; T E Schmid
Journal:  Radiat Environ Biophys       Date:  2012-01-07       Impact factor: 1.925

Review 2.  Microirradiation techniques in radiobiological research.

Authors:  Guido A Drexler; Miguel J Ruiz-Gómez
Journal:  J Biosci       Date:  2015-09       Impact factor: 1.826

3.  "Broadbeam" irradiation of mammalian cells using a vertical microbeam facility.

Authors:  J C G Jeynes; M J Merchant; L Barazzuol; M Barry; D Guest; V V Palitsin; G W Grime; I D C Tullis; P R Barber; B Vojnovic; K J Kirkby
Journal:  Radiat Environ Biophys       Date:  2013-08-21       Impact factor: 1.925

4.  Scanning irradiation device for mice in vivo with pulsed and continuous proton beams.

Authors:  Christoph Greubel; Walter Assmann; Christian Burgdorf; Günther Dollinger; Guanghua Du; Volker Hable; Alexander Hapfelmeier; Ralf Hertenberger; Peter Kneschaurek; Dörte Michalski; Michael Molls; Sabine Reinhardt; Barbara Röper; Stefan Schell; Thomas E Schmid; Christian Siebenwirth; Tatiana Wenzl; Olga Zlobinskaya; Jan J Wilkens
Journal:  Radiat Environ Biophys       Date:  2011-05-10       Impact factor: 1.925

5.  New challenges in radiobiology research with microbeams.

Authors:  Marco Durante; Anna A Friedl
Journal:  Radiat Environ Biophys       Date:  2011-06-12       Impact factor: 1.925

6.  The influence of reference radiation photon energy on high-LET RBE: comparison of human peripheral lymphocytes and human-hamster hybrid AL cells.

Authors:  T E Schmid; C Greubel; G Dollinger; E Schmid
Journal:  Radiat Environ Biophys       Date:  2017-01-31       Impact factor: 1.925

7.  Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System.

Authors:  Eric S Diffenderfer; Ioannis I Verginadis; Michele M Kim; Khayrullo Shoniyozov; Anastasia Velalopoulou; Denisa Goia; Mary Putt; Sarah Hagan; Stephen Avery; Kevin Teo; Wei Zou; Alexander Lin; Samuel Swisher-McClure; Cameron Koch; Ann R Kennedy; Andy Minn; Amit Maity; Theresa M Busch; Lei Dong; Costas Koumenis; James Metz; Keith A Cengel
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-02-01       Impact factor: 7.038

8.  Radiobiological influence of megavoltage electron pulses of ultra-high pulse dose rate on normal tissue cells.

Authors:  Lydia Laschinsky; Leonhard Karsch; Elisabeth Leßmann; Melanie Oppelt; Jörg Pawelke; Christian Richter; Michael Schürer; Elke Beyreuther
Journal:  Radiat Environ Biophys       Date:  2016-05-19       Impact factor: 1.925

Review 9.  Laser-driven beam lines for delivering intensity modulated radiation therapy with particle beams.

Authors:  Kerstin M Hofmann; Stefan Schell; Jan J Wilkens
Journal:  J Biophotonics       Date:  2012-08-29       Impact factor: 3.207

10.  Survival of tumor cells after proton irradiation with ultra-high dose rates.

Authors:  Susanne Auer; Volker Hable; Christoph Greubel; Guido A Drexler; Thomas E Schmid; Claus Belka; Günther Dollinger; Anna A Friedl
Journal:  Radiat Oncol       Date:  2011-10-18       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.