Literature DB >> 1987715

Ablation of the atrioventricular junction with radiofrequency energy using a new electrode catheter.

J J Langberg1, M Chin, D J Schamp, M A Lee, J Goldberger, D N Pederson, M Oeff, M D Lesh, J C Griffin, M M Scheinman.   

Abstract

Percutaneous catheter ablation using radiofrequency energy can be used to interrupt atrioventricular (AV) conduction in patients with supraventricular tachycardia refractory to drugs. Results of radiofrequency ablation of the AV junction using a custom-designed catheter with a large, 3-mm-long distal electrode, 2-mm interelectrode spacing, and a shaft with increased torsional rigidity were compared with those using a standard quadripolar electrode catheter (Bard EP). An electrocoagulator (Microvasive Bicap 4005) supplied unmodulated radiofrequency current at 550 kHz, which was applied between the distal electrode of the ablation catheter and a large skin electrode. With use of the modified catheter, 12 of 13 patients (92%) had persistent complete AV block induced with 7 +/- 5 applications of 18 +/- 6 W of radiofrequency power. In contrast, complete AV block was produced in only 9 of 18 (50%) historical control patients treated with the standard catheter, despite a similar number of applications (7 +/- 5) and power output (16 +/- 4 W). A rise in impedance, due to desiccation of tissue and coagulum formation, occurred earlier (28 +/- 18 vs 52 +/- 24 seconds, p less than 0.001) and more frequently (54 vs 40% of applications, p = 0.047) in patients treated with the standard catheter than in patients treated with the modified catheter. The use of a catheter designed to increase the surface area of electrode-tissue contact allows more radiofrequency energy to be delivered before a rise in impedance occurs and appears to increase the effectiveness of radiofrequency ablation of the AV junction.

Entities:  

Mesh:

Year:  1991        PMID: 1987715     DOI: 10.1016/0002-9149(91)90436-o

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Novel catheter technology for ablative cure of atrial fibrillation.

Authors:  M D Lesh; P Guerra; F X Roithinger; Y Goseki; C Diederich; W H Nau; M Maguire; K Taylor
Journal:  J Interv Card Electrophysiol       Date:  2000-01       Impact factor: 1.900

Review 2.  [Cardiology update. I: Electrophysiology].

Authors:  P Weismüller; H J Trappe
Journal:  Med Klin (Munich)       Date:  1999-01-15

3.  Treating Wolff-Parkinson-White syndrome.

Authors:  S O Núnáin; A J Camm; D E Ward
Journal:  BMJ       Date:  1991-12-07

4.  The Ablate and Pace Trial: a prospective study of catheter ablation of the AV conduction system and permanent pacemaker implantation for treatment of atrial fibrillation. APT Investigators.

Authors:  G N Kay; K A Ellenbogen; M Giudici; M M Redfield; L S Jenkins; M Mianulli; B Wilkoff
Journal:  J Interv Card Electrophysiol       Date:  1998-06       Impact factor: 1.900

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.