Literature DB >> 19876882

Leg length discrepancy in total hip arthroplasty with the use of cemented and uncemented femoral stems. A prospective radiological study.

Riaz Ahmad1, Vinod Sharma, Harvey Sandhu, Michael Bishay.   

Abstract

Leg length discrepancy may occur following total hip arthroplasty, with a potentially impaired functional outcome as a result. The aim of this study was to compare the leg length discrepancy between both cemented and uncemented femoral stems when used in total hip arthroplasty. A prospective radiological study of 200 consecutive primary total hip arthroplasties was performed between June 2005 and December 2006. Pre and post-operative radiographs were analysed. 56 (56%) of the total hip arthroplasties where an uncemented femoral stem was used had a leg length discrepancy over 1 cm. However only 23 (23%) of the total hip arthroplasties with a cemented femoral stem had a leg length discrepancy over 1 cm. The use of cemented femoral stems in total hip arthroplasty results in a lower incidence of leg length discrepancy, with a potentially better functional outcome.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19876882     DOI: 10.1177/112070000901900313

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  4 in total

1.  A higher reliability with a computed tomography scan-based three dimensional technique than with a two dimensional measurement for lower limb discrepancy in total hip arthroplasty planning.

Authors:  Elhadi Sariali; Matthias Mueller; Shahnaz Klouche
Journal:  Int Orthop       Date:  2021-08-04       Impact factor: 3.075

2.  Factors predisposing to claims and compensations for patient injuries following total hip and knee arthroplasty.

Authors:  Jutta Järvelin; Unto Häkkinen; Gunnar Rosenqvist; Ville Remes
Journal:  Acta Orthop       Date:  2012-03-08       Impact factor: 3.717

3.  Influence of leg length inequalities on pelvis and spine in patients with total hip arthroplasty.

Authors:  Marcel Betsch; Roman Michalik; Maximilian Graber; Michael Wild; Rüdiger Krauspe; Christoph Zilkens
Journal:  PLoS One       Date:  2019-08-27       Impact factor: 3.240

4.  Long-term follow-up outcomes for patients undergoing primary total hip arthroplasty with uncemented versus cemented femoral components: a retrospective observational study with a 5-year minimum follow-up.

Authors:  Tiejian Liu; Xiaoxiao Hua; Weiguang Yu; Jinluan Lin; Mingdong Zhao; Jun Liu; Xianshang Zeng
Journal:  J Orthop Surg Res       Date:  2019-11-15       Impact factor: 2.359

  4 in total