| Literature DB >> 19874601 |
Jose L Izquierdo-García1, Ignacio Rodríguez, Angelos Kyriazis, Palmira Villa, Pilar Barreiro, Manuel Desco, Jesús Ruiz-Cabello.
Abstract
BACKGROUND: Analysis of the plethora of metabolites found in the NMR spectra of biological fluids or tissues requires data complexity to be simplified. We present a graphical user interface (GUI) for NMR-based metabonomic analysis. The "Metabonomic Package" has been developed for metabonomics research as open-source software and uses the R statistical libraries.Entities:
Mesh:
Year: 2009 PMID: 19874601 PMCID: PMC2774703 DOI: 10.1186/1471-2105-10-363
Source DB: PubMed Journal: BMC Bioinformatics ISSN: 1471-2105 Impact factor: 3.169
Packages required to execute the Metabonomic GUI
| tcltk, tcltk2, tkrplot, scatterplot3d | |
| PROcess, caMassClass, FTICRMS, clusterSim, waved | |
| hddplot, MASS, gpls, pls, class, robustbase, relimp, Icens | |
| nnet, AMORE, neural | |
Example of an info file
| RF03 | Tobacco | Chronic |
| RF08 | Tobacco | Chronic |
| RF10 | Tobacco | Chronic |
| RF13 | Tobacco | Chronic |
| RF16 | Tobacco | Chronic |
| RF17 | Tobacco | Chronic |
| RF20 | Tobacco | Chronic |
| RF27 | Tobacco | Chronic |
| RF30 | Tobacco | Chronic |
| RF31 | Tobacco | Chronic |
| RF32 | Tobacco | Chronic |
| RF33 | Tobacco | Chronic |
| RF47 | Tobacco | Chronic |
| RF48 | Tobacco | Chronic |
| RF49 | Tobacco | Chronic |
| RF01 | Control | Control |
| RF02 | Control | Control |
| RF04 | Control | Control |
| RF07 | Control | Control |
| RF12 | Control | Control |
| RF21 | Control | Control |
| RF28 | Control | Control |
| RF43 | Control | Control |
| RF44 | Control | Control |
| RF45 | Control | Control |
| RF52 | Control | Control |
| RF53 | Control | Control |
| RF54 | Control | Control |
Figure 1Baseline (FTICRMS) display. Baseline correction of a proton-NMR spectrum using the Baseline (FTICRMS) display.
Figure 2Metabonomic GUI used for PCA. First and second principal component score plot of two class samples (control and tobacco).
Figure 3Metabonomic GUI used for LDA. LDA score plot of two class samples (control and tobacco) with the training model samples (black) and the testing model samples (blue). The cross-validation result is also returned.
Figure 4Metabonomic GUI used for PLS-DA. Interactive graph (right) with the first three PLS components score plot of two classes of samples (healthy and tobacco). The black samples are the samples used to build the model and the blue samples are the validation samples. In addition, the validation result and the explained variance are shown.
Figure 5Extra tools. Metabonomic GUI tools to visualize and overlap the spectra (right) and to show the values of all samples in a given chemical position (left).
Validation results for different multivariate methods incorporated in the GUI
| LDA | 86% | 100% | 100% | 83% |
| 100% | 100% | 100% | 100% | |
| PLS (Kernel) | 100% | 100% | 100% | 100% |
| 86% | 100% | 100% | 83% | |
| Feedforward neural network | 86% | 100% | 100% | 83% |