Literature DB >> 1987243

Recognition and embolic potential of intraaortic atherosclerotic debris.

D G Karalis1, K Chandrasekaran, M F Victor, J J Ross, G S Mintz.   

Abstract

Atherosclerotic disease of the thoracic aorta is common in the elderly and patients with clinical coronary artery disease. Although embolization can occur from atherosclerotic debris within the thoracic aorta, it is not commonly considered in the differential diagnosis of the source of a systemic embolism. In the current study, the prevalence, clinical significance and embolic potential of intraaortic atherosclerotic debris as detected by transesophageal echocardiography was determined. Intraaortic atherosclerotic debris was identified in 38 (7%) of 556 patients undergoing transesophageal echocardiography. An embolic event occurred among 11 (31%) of the 36 study patients with intraaortic atherosclerotic debris. The incidence of an embolic event was higher when the debris was pedunculated and highly mobile (8 [73%] of 11 patients) than when it was layered and immobile (3 [12%] of 25 patients) (p less than 0.002). Among 15 patients undergoing an invasive procedure of the aorta, the incidence of embolism was 27%. In conclusion, in a patient with an embolic event, the thoracic aorta should be considered as a potential source. Transesophageal echocardiography can reliably detect intraaortic atherosclerotic debris, and when it is identified, an invasive aortic procedure should be avoided if possible.

Entities:  

Mesh:

Year:  1991        PMID: 1987243     DOI: 10.1016/0735-1097(91)90706-f

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  37 in total

1.  Limitations of transoesophageal echocardiography in patients with focal cerebral ischaemic events.

Authors:  P A Tunick; I Kronzon
Journal:  Br Heart J       Date:  1992-12

2.  Limitations of transoesophageal echocardiography in patients with focal cerebral ischaemic events.

Authors:  P Wilmshurst
Journal:  Br Heart J       Date:  1992-12

Review 3.  Transesophageal echocardiography and stroke.

Authors:  Timothy D Woods
Journal:  Curr Atheroscler Rep       Date:  2005-07       Impact factor: 5.113

4.  Limitations of transoesophageal echocardiography in patients with focal cerebral ischaemic events.

Authors:  M De Belder
Journal:  Br Heart J       Date:  1992-12

5.  Alcohol consumption and atherosclerotic burden in the proximal thoracic aorta.

Authors:  Shun Kohsaka; Zhezhen Jin; Tatjana Rundek; Shunichi Homma; Ralph L Sacco; Marco R Di Tullio
Journal:  Atherosclerosis       Date:  2011-08-16       Impact factor: 5.162

6.  Echocardiography in stroke and transient ischaemic attack.

Authors:  J B Chambers; M A de Belder; D Moore
Journal:  Heart       Date:  1997-08       Impact factor: 5.994

Review 7.  Echocardiography in the diagnosis of thoracic aortic pathology.

Authors:  F D Tice; J Kisslo
Journal:  Int J Card Imaging       Date:  1993

8.  Complex atheromatosis of the aortic arch in cerebral infarction.

Authors:  Ramón Pujadas Capmany; Montserrat Oliveras Ibañez; Xavier Jané Pesquer
Journal:  Curr Cardiol Rev       Date:  2010-08

9.  Endovascular repair of descending thoracic aortic aneurysm: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2005-11-01

Review 10.  Thrombolysis in thromboembolic diseases.

Authors:  D C Gulba; R Dechend
Journal:  Ann Hematol       Date:  1994-10       Impact factor: 3.673

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.