OBJECTIVES: The purpose of the laboratory tests of the current investigation was to examine how visual cues impact directional (DIR) benefit and preference for the DIR microphone hearing aid (re: the omnidirectional [OMNI] microphone). Specifically, three hypotheses were examined: (1) the presence of visual cues would improve OMNI-aided performance to ceiling levels and therefore reduce DIR benefit and preference, (2) DIR benefit measured in the audiovisual (AV) condition could not be predicted by that measured using auditory-only (AO) testing, and (3) with visual cues, listeners with greater lipreading skills would perceive less DIR benefit than did listeners with lesser lipreading skills.
DESIGN: Twenty-four adults with sensorineural hearing loss were recruited. Their speech recognition performances were measured in two hearing aid microphone modes (DIR and OMNI), at various signal-to-noise ratios (SNR, -10 to +10 dB in 4-dB steps) and under two presentation conditions (AV and AO) by using the AV version of the Connected Speech Test. Microphone preference (DIR versus OMNI) was also assessed with and without visual cues at each of the SNRs by using the same Connected Speech Test sentences. Lipreading skills were measured using the Utley test.
RESULTS: The speech recognition data revealed that the participants obtained significantly less DIR benefit in the AV condition because their AV performances were at the ceiling level. Consistent with this, the likelihood of preferring DIR processing was significantly reduced when visual cues were available to the listeners. Further, DIR benefit measured in the AV condition was not correlated with that measured in the AO condition while being significantly and negatively correlated with lipreading skill.
CONCLUSIONS: These results suggest that AO laboratory testing overestimates the DIR benefit and preference for DIR processing that hearing aid users may have in most face-to-face conversations in typical SNR, real-world environments. Additionally, because the DIR benefit measured in the AV condition cannot be predicted by the benefit score obtained from traditional AO laboratory testing, the effect of visual cues should be considered in establishing a valid laboratory/clinical environment and protocol for DIR microphone hearing aid testing. In light of these findings, consultations should be provided for hearing aid users with superior lipreading skills to help them adjust their expectations regarding the possibly small perceivable benefit gained from DIR microphone hearing aids.

Entities:  

Mesh:

Year:  2010        PMID: 19864954     DOI: 10.1097/AUD.0b013e3181bc767e

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  10 in total

1.  Characteristics of Real-World Signal to Noise Ratios and Speech Listening Situations of Older Adults With Mild to Moderate Hearing Loss.

Authors:  Yu-Hsiang Wu; Elizabeth Stangl; Octav Chipara; Syed Shabih Hasan; Anne Welhaven; Jacob Oleson
Journal:  Ear Hear       Date:  2018 Mar/Apr       Impact factor: 3.570

2.  Working Memory and Speech Recognition in Noise Under Ecologically Relevant Listening Conditions: Effects of Visual Cues and Noise Type Among Adults With Hearing Loss.

Authors:  Christi W Miller; Erin K Stewart; Yu-Hsiang Wu; Christopher Bishop; Ruth A Bentler; Kelly Tremblay
Journal:  J Speech Lang Hear Res       Date:  2017-08-16       Impact factor: 2.297

3.  Benefit From Directional Microphone Hearing Aids: Objective and Subjective Evaluations.

Authors:  Hee-Sung Park; Il Joon Moon; Sun Hwa Jin; Ji Eun Choi; Yang-Sun Cho; Sung Hwa Hong
Journal:  Clin Exp Otorhinolaryngol       Date:  2015-08-13       Impact factor: 3.372

4.  AudioSense: Enabling Real-time Evaluation of Hearing Aid Technology In-Situ.

Authors:  Syed Shabih Hasan; Farley Lai; Octav Chipara; Yu-Hsiang Wu
Journal:  Proc IEEE Int Symp Comput Based Med Syst       Date:  2013

Review 5.  An evidence-based systematic review of directional microphones and digital noise reduction hearing aids in school-age children with hearing loss.

Authors:  Ryan W McCreery; Rebecca A Venediktov; Jaumeiko J Coleman; Hillary M Leech
Journal:  Am J Audiol       Date:  2012-08-02       Impact factor: 1.493

6.  Construct Validity of the Ecological Momentary Assessment in Audiology Research.

Authors:  Yu-Hsiang Wu; Elizabeth Stangl; Xuyang Zhang; Ruth A Bentler
Journal:  J Am Acad Audiol       Date:  2015 Nov-Dec       Impact factor: 1.664

7.  GPS predicts stability of listening environment characteristics in one location over time among older hearing aid users.

Authors:  Erik J Jorgensen; Elizabeth Stangl; Octav Chipara; Helin Hernandez; Jacob Oleson; Yu-Hsiang Wu
Journal:  Int J Audiol       Date:  2020-10-19       Impact factor: 2.437

Review 8.  How neuroscience relates to hearing aid amplification.

Authors:  K L Tremblay; C W Miller
Journal:  Int J Otolaryngol       Date:  2014-06-18

9.  Efficacy and Effectiveness of Advanced Hearing Aid Directional and Noise Reduction Technologies for Older Adults With Mild to Moderate Hearing Loss.

Authors:  Yu-Hsiang Wu; Elizabeth Stangl; Octav Chipara; Syed Shabih Hasan; Sean DeVries; Jacob Oleson
Journal:  Ear Hear       Date:  2019 Jul/Aug       Impact factor: 3.570

10.  Internet video telephony allows speech reading by deaf individuals and improves speech perception by cochlear implant users.

Authors:  Georgios Mantokoudis; Claudia Dähler; Patrick Dubach; Martin Kompis; Marco D Caversaccio; Pascal Senn
Journal:  PLoS One       Date:  2013-01-24       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.