Literature DB >> 19863412

Progression of emphysema evaluated by MRI using hyperpolarized (3)He (HP (3)He) measurements in patients with alpha-1-antitrypsin (A1AT) deficiency compared with CT and lung function tests.

T Stavngaard1, L Vejby Søgaard, M Batz, L M Schreiber, A Dirksen.   

Abstract

BACKGROUND: The progression of emphysema is traditionally measured by pulmonary function test, with forced expiratory volume in 1 s (FEV(1)) being the most accepted and used measurement. However, FEV(1) is insensitive in detecting mild/slow progression of emphysema because of low reproducibility as compared to yearly decline.
PURPOSE: To investigate the progression of emphysema over a period of 2 years using diffusion-weighted hyperpolarized (HP) (3)He magnetic resonance imaging (MRI) in patients with alpha-1-antitrypsin (A1AT) deficiency.
MATERIAL AND METHODS: Nine patients with severe A1AT deficiency were studied over a period of 2 years (baseline, year 1, and year 2) with HP (3)He MRI using apparent diffusion coefficient (ADC), lung function tests (FEV(1) and carbon monoxide lung diffusion capacity [D(L,CO)]), and computed tomography (CT) using densitometric parameters (15th percentile density [CT-PD15] and relative area of emphysema below -910 HU [CT-RA-910]).
RESULTS: Seven patients were scanned three times, one patient two times, and one patient only at baseline. The mean increase in ADC values from first to last HP (3)He MR scanning was 3.8% (0.014 cm(2)/s [SD 0.024 cm(2)/s]; not significant). The time trends for FEV(1), D(L,CO), CT-PD15, and CT-RA-910 were all statistically significant. We found a high correlation between ADC and D(L,CO) (P<0.001).
CONCLUSION: This pilot study indicates the possible use of nonionizing HP (3)He MRI for monitoring the progression of emphysema. However, in the future, larger studies are needed to confirm these preliminary results.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19863412     DOI: 10.3109/02841850903213822

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  3 in total

1.  Diffusion-weighted hyperpolarized 129Xe MRI in healthy volunteers and subjects with chronic obstructive pulmonary disease.

Authors:  S Sivaram Kaushik; Zackary I Cleveland; Gary P Cofer; Gregory Metz; Denise Beaver; John Nouls; Monica Kraft; William Auffermann; Jan Wolber; H Page McAdams; Bastiaan Driehuys
Journal:  Magn Reson Med       Date:  2010-12-16       Impact factor: 4.668

2.  Effect of lung inflation level on hyperpolarized 3He apparent diffusion coefficient measurements in never-smokers.

Authors:  Ahmed F Halaweish; Eric A Hoffman; Daniel R Thedens; Matthew K Fuld; Jered P Sieren; Edwin J R van Beek
Journal:  Radiology       Date:  2013-04-16       Impact factor: 11.105

3.  Role of computed tomography in quantitative assessment of emphysema.

Authors:  Agnieszka Choromańska; Katarzyna J Macura
Journal:  Pol J Radiol       Date:  2012-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.