Sonographic changes after removing all benign breast masses with sonographically guided vacuum-assisted biopsy.

Eun Sook Ko1, Heon Han, Byung Hee Lee, Du Hwan Choe.   

Abstract

BACKGROUND: Total removal of benign breast masses by vacuum-assisted biopsy (VAB) is now increasingly accepted as a treatment option. However, little is known about whether this procedure produces early changes on follow-up sonography and, if so, how often and what factors might influence them.
PURPOSE: To evaluate sonographic changes after total removal of benign breast masses using sonographically guided VAB and to determine the influencing factors.
MATERIAL AND METHODS: We evaluated sonographic changes prospectively 1 week, 1 month, and 6 months after biopsying 32 benign masses from which all sonographic evidence had been removed during sonographically guided directional VAB performed with 8- or 11-gauge needles. Procedural factors were documented and compared with sonographic findings.
RESULTS: At 1-week follow-up, hematomas were observed in 84% (27/32) of the lesions. After 1 month, while the hematomas had resolved in all but five lesions, focal new architectural distortion had developed in 26 (90%) lesions; 11 lesions were graded as severe, mimicking malignancy. After 6 months, 23 lesions with various degrees of architectural distortion were observed. Six of the 32 lesions (19%) contained a residual lesion. No statistically significant association between sonographic findings and procedural variables was identified, except between the degree of hematoma and lesion size.
CONCLUSION: The total removal of benign breast masses using sonographically guided VAB frequently produces changes on follow-up sonography after 6 months. Although these changes failed to show statistical significance with procedural factors, a larger dedicated study is needed.

Entities:  

Mesh:

Year:  2009        PMID: 19863404     DOI: 10.3109/02841850903130836

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach.

Authors:  Stephen P Povoski; Rafael E Jimenez; Wenle P Wang
Journal:  World J Surg Oncol       Date:  2011-08-11       Impact factor: 2.754

2.  Use of Core Needle Biopsy rather than Fine-Needle Aspiration Cytology in the Diagnostic Approach of Breast Cancer.

Authors:  Paola Pagni; Flaminia Spunticchia; Simona Barberi; Giuliana Caprio; Carlo Paglicci
Journal:  Case Rep Oncol       Date:  2014-07-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.