Literature DB >> 19859960

T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

José G Raya1, Olaf Dietrich, Annie Horng, Jürgen Weber, Maximilian F Reiser, Christian Glaser.   

Abstract

T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the accuracy and precision of the traditional fit methods (linear least-squares regression and nonlinear fit to an exponential) and two new noise-corrected fit methods: fit to a noise-corrected exponential and fit of the noise-corrected squared signal intensity to an exponential. Accuracy and precision have been analyzed in simulations, in phantom measurements, and in seven repetitive acquisitions of the patellar cartilage in six healthy volunteers. Traditional fit methods lead to a poor accuracy for low T2, with overestimations of the exact T2 up to 500%. The noise-corrected fit methods demonstrate a very good accuracy for all T2 values and signal-to-noise ratio. Even more, the fit to a noise-corrected exponential results in precisions comparable to the best achievable precisions (Cramér-Rao lower bound). For in vivo images, the traditional fit methods considerably overestimate T2 near the bone-cartilage interface. Therefore, using an adequate fit method may substantially improve the sensitivity of T2 to detect pathology in cartilage and change in T2 follow-up examinations. Copyright (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 19859960     DOI: 10.1002/mrm.22178

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  74 in total

1.  Bicomponent ultrashort echo time T2* analysis for assessment of patients with patellar tendinopathy.

Authors:  Richard Kijowski; John J Wilson; Fang Liu
Journal:  J Magn Reson Imaging       Date:  2017-03-06       Impact factor: 4.813

2.  Association of magnetic resonance imaging-based knee cartilage T2 measurements and focal knee lesions with knee pain: data from the Osteoarthritis Initiative.

Authors:  Thomas Baum; Gabby B Joseph; Ahilan Arulanandan; Lorenzo Nardo; Warapat Virayavanich; Julio Carballido-Gamio; Michael C Nevitt; John Lynch; Charles E McCulloch; Thomas M Link
Journal:  Arthritis Care Res (Hoboken)       Date:  2012-02       Impact factor: 4.794

3.  Baseline mean and heterogeneity of MR cartilage T2 are associated with morphologic degeneration of cartilage, meniscus, and bone marrow over 3 years--data from the Osteoarthritis Initiative.

Authors:  G B Joseph; T Baum; H Alizai; J Carballido-Gamio; L Nardo; W Virayavanich; J A Lynch; M C Nevitt; C E McCulloch; S Majumdar; T M Link
Journal:  Osteoarthritis Cartilage       Date:  2012-04-11       Impact factor: 6.576

Review 4.  [Biochemical magnetic resonance imaging of intervertebral discs and facet joints].

Authors:  D Stelzeneder; S Trattnig
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

Review 5.  Errors in quantitative T1rho imaging and the correction methods.

Authors:  Weitian Chen
Journal:  Quant Imaging Med Surg       Date:  2015-08

6.  Predicting early symptomatic osteoarthritis in the human knee using machine learning classification of magnetic resonance images from the osteoarthritis initiative.

Authors:  Beth G Ashinsky; Mustapha Bouhrara; Christopher E Coletta; Benoit Lehallier; Kenneth L Urish; Ping-Chang Lin; Ilya G Goldberg; Richard G Spencer
Journal:  J Orthop Res       Date:  2017-03-23       Impact factor: 3.494

Review 7.  Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping.

Authors:  Rachel K Surowiec; Erin P Lucas; Charles P Ho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-30       Impact factor: 4.342

8.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

9.  Repeatability of ultrashort echo time-based two-component T2* measurements on cartilages in human knee at 3 T.

Authors:  Yongxian Qian; Ashley A Williams; Constance R Chu; Fernando E Boada
Journal:  Magn Reson Med       Date:  2012-10-03       Impact factor: 4.668

10.  Transection of the medial meniscus anterior horn results in cartilage degeneration and meniscus remodeling in a large animal model.

Authors:  Sonia Bansal; Liane M Miller; Jay M Patel; Kyle D Meadows; Michael R Eby; Kamiel S Saleh; Anthony R Martin; Brendan D Stoeckl; Michael W Hast; Dawn M Elliott; Miltiadis H Zgonis; Robert L Mauck
Journal:  J Orthop Res       Date:  2020-04-23       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.