Literature DB >> 19859950

Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T.

Matthias Weigel1, Gunther Helms, Juergen Hennig.   

Abstract

Magnetization transfer effects represent a major source of contrast in multislice turbo spin echo sequences (TSE)/fast spin echo sequences. Generally, low refocusing flip angles have become common in such MRI sequences, especially to mitigate specific absorption rate problems. Since the strength of magnetization transfer effects is related to the radiofrequency power and therefore specific absorption rate applied, magnetization transfer induced signal attenuations are investigated for a variety of TSE sequences with low constant and variable flip angles. Noticeable differences between the sequences have been observed. In particular, fewer signal attenuations are observed for TSE with low flip angles such as hyperecho-TSE and smooth transitions between pseudo steady states-TSE, leading to contrast that is less dependent on the number of slices. It is shown that the strength of the magnetization transfer-induced signal attenuations can be understood and described by a physical framework, which is based on the mean square flip angle of a given TSE sequence. Copyright (c) 2009 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2010        PMID: 19859950     DOI: 10.1002/mrm.22145

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Alternate ascending/descending directional navigation approach for imaging magnetization transfer asymmetry.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-07-30       Impact factor: 4.668

2.  Analysis of magnetization transfer (MT) influence on quantitative mapping of T2 relaxation time.

Authors:  Dvir Radunsky; Tamar Blumenfeld-Katzir; Osnat Volovyk; Assaf Tal; Daniel Barazany; Galia Tsarfaty; Noam Ben-Eliezer
Journal:  Magn Reson Med       Date:  2019-03-12       Impact factor: 4.668

Review 3.  Trends and properties of human cerebral cortex: correlations with cortical myelin content.

Authors:  Matthew F Glasser; Manu S Goyal; Todd M Preuss; Marcus E Raichle; David C Van Essen
Journal:  Neuroimage       Date:  2013-04-06       Impact factor: 6.556

4.  Detecting hepatocellular carcinoma in gadoxetic-acid-enhanced hepatobiliary-phase MR imaging at 3T: comparing high and low flip angle.

Authors:  Mina Song; Hyeon Je Cho; Yun Ku Cho; Mi Young Kim; Sang Ik Noh; Soo Hyun Yang
Journal:  Jpn J Radiol       Date:  2013-10-17       Impact factor: 2.374

5.  Multi-slice myelin water imaging for practical clinical applications at 3.0 T.

Authors:  Junyu Guo; Qing Ji; Wilburn E Reddick
Journal:  Magn Reson Med       Date:  2012-11-06       Impact factor: 4.668

6.  A multi-inversion multi-echo spin and gradient echo echo planar imaging sequence with low image distortion for rapid quantitative parameter mapping and synthetic image contrasts.

Authors:  Mary Kate Manhard; Jason Stockmann; Congyu Liao; Daniel Park; Sohyun Han; Merlin Fair; Maaike van den Boomen; Jon Polimeni; Berkin Bilgic; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2021-03-25       Impact factor: 3.737

7.  Investigation of inter-slice magnetization transfer effects as a new method for MTR imaging of the human brain.

Authors:  Jeffrey W Barker; Paul Kyu Han; Seung Hong Choi; Kyongtae Ty Bae; Sung-Hong Park
Journal:  PLoS One       Date:  2015-02-09       Impact factor: 3.240

8.  Inter-Slice Blood Flow and Magnetization Transfer Effects as A New Simultaneous Imaging Strategy.

Authors:  Paul Kyu Han; Jeffrey W Barker; Ki Hwan Kim; Seung Hong Choi; Kyongtae Ty Bae; Sung-Hong Park
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240

Review 9.  Advances in noninvasive myelin imaging.

Authors:  Florence Heath; Samuel A Hurley; Heidi Johansen-Berg; Cassandra Sampaio-Baptista
Journal:  Dev Neurobiol       Date:  2017-11-10       Impact factor: 3.964

10.  Effect of low refocusing angle in T1-weighted spin echo and fast spin echo MRI on low-contrast detectability: a comparative phantom study at 1.5 and 3 Tesla.

Authors:  Subhendra N Sarkar; Jason L Mangosing; Pooja R Sarkar
Journal:  Biomed Res Int       Date:  2013-08-06       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.