Literature DB >> 19858237

The impact of different biocompatible coated cardiopulmonary bypass circuits on inflammatory response and oxidative stress.

N Sohn1, J Marcoux, T Mycyk, J Krahn, Qh Meng.   

Abstract

This study was to compare the impact of different biocompatible coated circuits on inflammatory response and oxidative stress induced during cardiopulmonary bypass (CPB). Seventy-eight patients undergoing elective coronary artery bypass grafting (CABG) with CPB were randomly assigned to five groups with different biocompatible coated circuits: Trillium, Bioline, Phosphorylcholine, Polymethoxyethyl acrylate (PMEA), and the uncoated control group. Blood was drawn at three different time points: before CPB, 6 and 72 hours post CPB. Unlike the Trillium group, serum levels of TNF-alpha in the Bioline and Phosphorylcholine groups significantly increased only at 72 hours post CPB (p < 0.05). Serum levels of IL-6 significantly increased at 6 and 72 hours post CPB in all groups (p < 0.01). The Trillium group showed a significant increase of IL-10 compared to the control group at 72 hours post CPB (p < 0.05). Serum levels of NOx in the Phosphorylcholine group significantly decreased at 6 hours post CPB compared to baseline (p < 0.05). Both the Bioline and Phosphorylcholine groups showed statistical decreases in serum NOx levels compared with other groups at 6 hours post CPB (p < 0.05). A significant difference in NOx levels between the Bioline and the control group was also observed at 72 hours post CPB. Myeloperoxidase levels were significantly elevated at 6 and 72 hours post CPB in all groups (p < 0.05). Inflammatory response and oxidative stress are elevated during CABG with CPB. Heparin-coated and the Phosphorylcholine-coated circuits induce less inflammatory responses and oxidative stress compared to other circuits.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19858237     DOI: 10.1177/0267659109351218

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  18 in total

1.  Predicting adult perfusion practice trends and the adoption of evidence-based practice.

Authors:  Margaret A Relle; Jennifer M Hutchinson; Adam Mattison; Alicia Sievert; Anthony G Shackelford
Journal:  J Extra Corpor Technol       Date:  2014-03

Review 2.  VV extracorporeal life support for the Third Millennium: will we need anticoagulation?

Authors:  Danny Eytan; Yuval Bitterman; Gail M Annich
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

3.  The effect of CD47 modified polymer surfaces on inflammatory cell attachment and activation.

Authors:  Stanley J Stachelek; Matthew J Finley; Ivan S Alferiev; Fengxiang Wang; Richard K Tsai; Edward C Eckells; Nancy Tomczyk; Jeanne M Connolly; Dennis E Discher; David M Eckmann; Robert J Levy
Journal:  Biomaterials       Date:  2011-03-22       Impact factor: 12.479

Review 4.  Is a fully heparin-bonded cardiopulmonary bypass circuit superior to a standard cardiopulmonary bypass circuit?

Authors:  Sarah Mahmood; Haris Bilal; Mahvash Zaman; Augustine Tang
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-06

5.  Whether heparin causes hemolysis: an in silico and in vitro study.

Authors:  Sheemona Chowdhary; Deepak Kumar; Sumanpreet Kaur; Rajasri Bhattacharyya; Dibyajyoti Banerjee; Rupesh Kumar
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2022-03-21

Review 6.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

Review 7.  Prevention of lung injury in cardiac surgery: a review.

Authors:  Robert W Young
Journal:  J Extra Corpor Technol       Date:  2014-06

8.  Thrombosis and Bleeding in Extracorporeal Membrane Oxygenation (ECMO) Without Anticoagulation: A Systematic Review.

Authors:  Sven R Olson; Catherine R Murphree; David Zonies; Andrew D Meyer; Owen J T Mccarty; Thomas G Deloughery; Joseph J Shatzel
Journal:  ASAIO J       Date:  2021-03-01       Impact factor: 3.826

9.  Toward an artificial endothelium: Development of blood-compatible surfaces for extracorporeal life support.

Authors:  Teryn R Roberts; Mark R S Garren; Hitesh Handa; Andriy I Batchinsky
Journal:  J Trauma Acute Care Surg       Date:  2020-08       Impact factor: 3.697

10.  The importance of intraoperative selenium blood levels on organ dysfunction in patients undergoing off-pump cardiac surgery: a randomised controlled trial.

Authors:  Ana Stevanovic; Mark Coburn; Ares Menon; Rolf Rossaint; Daren Heyland; Gereon Schälte; Thilo Werker; Willibald Wonisch; Michael Kiehntopf; Andreas Goetzenich; Steffen Rex; Christian Stoppe
Journal:  PLoS One       Date:  2014-08-13       Impact factor: 3.240

View more