Literature DB >> 19855978

Microscopic magnetic resonance in congenital diaphragmatic hernia and associated malformations in rats.

Montserrat Bret1, Ana Lourdes Luis, Emilio Cuesta, Federica Pederiva, Rosa Aras, Leopoldo Martinez, Juan A Tovar.   

Abstract

BACKGROUND/AIM: The research on congenital diaphragmatic hernia (CDH) is often carried out on the nitrofen fetal rat model in which most investigations involve microdissections and fastidious assessment of serial sections of different anatomic areas. Current microscopic magnetic resonance (MMR) equipment allows detailed anatomic studies of alive, fresh or fixed fetuses. The purpose of the present study was to demonstrate that CDH itself and most of the associated malformations are adequately imaged and measured by MMR.
MATERIALS AND METHODS: Fetuses from pregnant rats treated with either i.g. vehicle (control, n = 10) or 100 mg nitrofen (only those with CDH, n = 18) on E9.5 were recovered on E21 (term = E22) and total body was scanned by MMR under sedation in a 7 T MRI system (Bruker Medical, Ettlingen, Germany). CDH was detected with a coronal multislice fast spin echo sequence with a long repetition time and short effective echo time. Oblique MPR and 3D reconstructions were used. All studies were processed with attention to the hernia and its contents and the structure of the tracheobronchial tree and the lung, the heart and great vessels, the thymus and cervico-thoracic vertebrae. The findings in both groups were compared.
RESULTS: Congenital diaphragmatic hernia, lung hypoplasia and parenchymal features were clearly depicted. Tracheal ring anomalies were also demonstrated. The thymus was significantly smaller in CDH pups (2.9 x 1 x 2.4 mm) than in controls (4 x 1.3 x 2.8 mm) (p < 0.01). MRI was particularly performant for imaging cardiovascular anomalies: 4 double aortic arches, 3 Fallots, 3 right aortic arches, 3 ventricular septal defects and 1 aberrant subclavian artery.
CONCLUSIONS: Microscopic magnetic resonance involves refined and expensive equipment but it provides a powerful research tool for the study of CDH and other malformations in rat fetuses. Further work on this area is warranted.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19855978     DOI: 10.1007/s00383-009-2518-4

Source DB:  PubMed          Journal:  Pediatr Surg Int        ISSN: 0179-0358            Impact factor:   1.827


  38 in total

1.  Three-dimensional digital mouse atlas using high-resolution MRI.

Authors:  M Dhenain; S W Ruffins; R E Jacobs
Journal:  Dev Biol       Date:  2001-04-15       Impact factor: 3.582

2.  Embryology of congenital diaphragmatic hernia.

Authors:  D Kluth; R Keijzer; M Hertl; D Tibboel
Journal:  Semin Pediatr Surg       Date:  1996-11       Impact factor: 2.754

Review 3.  Current status of cardiac MRI in small animals.

Authors:  J-P Vallée; M K Ivancevic; D Nguyen; D R Morel; M Jaconi
Journal:  MAGMA       Date:  2004-12-16       Impact factor: 2.310

4.  Nitrofen-induced diaphragmatic hernias in rats: an animal model.

Authors:  D Kluth; R Kangah; P Reich; R Tenbrinck; D Tibboel; W Lambrecht
Journal:  J Pediatr Surg       Date:  1990-08       Impact factor: 2.545

5.  In vivo, in utero microscopic magnetic resonance imaging: application in a rat model of diaphragmatic hernia.

Authors:  A K Hoydu; Y Kitano; A Kriss; H Hensley; P Bergey; A Flake; A Hubbard; J S Leigh
Journal:  Magn Reson Med       Date:  2000-08       Impact factor: 4.668

Review 6.  Making the mouse embryo transparent: identifying developmental malformations using magnetic resonance imaging.

Authors:  Jürgen E Schneider; Shoumo Bhattacharya
Journal:  Birth Defects Res C Embryo Today       Date:  2004-09

7.  Effect of the reperfusion after cerebral ischemia in neonatal rats using MRI monitoring.

Authors:  Sebastien Fau; Chrystelle Po; Brigitte Gillet; Stephane Sizonenko; Jean Mariani; Philippe Meric; Christiane Charriaut-Marlangue
Journal:  Exp Neurol       Date:  2007-09-15       Impact factor: 5.330

8.  Manganese-enhanced magnetic resonance imaging of hypoxic-ischemic brain injury in the neonatal rat.

Authors:  Marius Widerøe; Øystein Olsen; Tina Bugge Pedersen; Pål Erik Goa; Annemieke Kavelaars; Cobi Heijnen; Jon Skranes; Ann-Mari Brubakk; Christian Brekken
Journal:  Neuroimage       Date:  2008-12-24       Impact factor: 6.556

9.  Tracheal innervation is abnormal in rats with experimental congenital diaphragmatic hernia.

Authors:  Federica Pederiva; Rosa Aras Lopez; Leopoldo Martinez; Juan A Tovar
Journal:  J Pediatr Surg       Date:  2009-06       Impact factor: 2.545

10.  High-resolution imaging of normal anatomy, and neural and adrenal malformations in mouse embryos using magnetic resonance microscopy.

Authors:  Jürgen E Schneider; Simon D Bamforth; Cassandra R Farthing; Kieran Clarke; Stefan Neubauer; Shoumo Bhattacharya
Journal:  J Anat       Date:  2003-02       Impact factor: 2.610

View more
  1 in total

1.  Microscopic magnetic resonance imaging of the thoracic venous system in rats with congenital diaphragmatic hernia.

Authors:  A L Luis; M Bret; E Cuesta; R M Aras; Liu Xiaomei; J L Encinas; L Martinez; J A Tovar
Journal:  Pediatr Surg Int       Date:  2011-02       Impact factor: 1.827

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.