INTRODUCTION: Rapid intravascular access is a prerequisite component of emergency care and resuscitation. Peripheral intravenous (IV) access is the first-choice for most of the medical or trauma patients, but may be delayed in emergency conditions because of various difficulties. Elsewhere, intraosseous (IO) access may now be easily performed with a new semi-automatic battery-powered IO-insertion device (EZ-IO. The aim of this study was to compare the overall time to establish IO infusion with the EZ-IO device and the equivalent time for peripheral IV infusion, performed by emergency personnel in standard (No-CBRN) and in chemical, biological, radiological, and nuclear (CBRN) protective equipment. METHODS: Nine nurses and 16 physicians randomly performed 4 procedures on a training manikin: IV and IO access under No-CBRN conditions and IV and IO under CBRN conditions. The time for each infusion attempt included all the steps essential for a simulated safe clinical use of infusion. RESULTS: Under No-CBRN conditions, the time to establish IO infusion was shorter than the equivalent IV time (50+/-9 vs 70+/-30s). Similarly, under CBRN conditions, the time for IO infusion was shorter than for IV infusion (65+/-17 vs 104+/-30s). The mean time saved by IO infusion over IV infusion was respectively 20+/-24s (P<0.001) and 39+/-20s (P<0.001) under No-CBRN and CBRN conditions. CONCLUSION: The time to establish IO infusion was significantly shorter than that for peripheral IV infusion, under both No-CBRN and CBRN conditions. Further clinical studies are required to confirm that IO access would effectively save time over IV access in real pre-hospital emergency settings. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
INTRODUCTION: Rapid intravascular access is a prerequisite component of emergency care and resuscitation. Peripheral intravenous (IV) access is the first-choice for most of the medical or traumapatients, but may be delayed in emergency conditions because of various difficulties. Elsewhere, intraosseous (IO) access may now be easily performed with a new semi-automatic battery-powered IO-insertion device (EZ-IO. The aim of this study was to compare the overall time to establish IO infusion with the EZ-IO device and the equivalent time for peripheral IV infusion, performed by emergency personnel in standard (No-CBRN) and in chemical, biological, radiological, and nuclear (CBRN) protective equipment. METHODS: Nine nurses and 16 physicians randomly performed 4 procedures on a training manikin: IV and IO access under No-CBRN conditions and IV and IO under CBRN conditions. The time for each infusion attempt included all the steps essential for a simulated safe clinical use of infusion. RESULTS: Under No-CBRN conditions, the time to establish IO infusion was shorter than the equivalent IV time (50+/-9 vs 70+/-30s). Similarly, under CBRN conditions, the time for IO infusion was shorter than for IV infusion (65+/-17 vs 104+/-30s). The mean time saved by IO infusion over IV infusion was respectively 20+/-24s (P<0.001) and 39+/-20s (P<0.001) under No-CBRN and CBRN conditions. CONCLUSION: The time to establish IO infusion was significantly shorter than that for peripheral IV infusion, under both No-CBRN and CBRN conditions. Further clinical studies are required to confirm that IO access would effectively save time over IV access in real pre-hospital emergency settings. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.
Authors: William J Brady; Summer Chavez; Michael Gottlieb; Stephen Y Liang; Brandon Carius; Alex Koyfman; Brit Long Journal: Am J Emerg Med Date: 2022-04-27 Impact factor: 4.093
Authors: Marek Malysz; Marek Dabrowski; Bernd W Böttiger; Jacek Smereka; Klaudia Kulak; Agnieszka Szarpak; Milosz Jaguszewski; Krzysztof J Filipiak; Jerzy R Ladny; Kurt Ruetzler; Lukasz Szarpak Journal: Cardiol J Date: 2020-05-18 Impact factor: 2.737
Authors: Richard Schalk; Uwe Schweigkofler; Gösta Lotz; Kai Zacharowski; Leo Latasch; Christian Byhahn Journal: Scand J Trauma Resusc Emerg Med Date: 2011-10-26 Impact factor: 2.953
Authors: Jacek Smereka; Lukasz Szarpak; Krzysztof J Filipiak; Milosz Jaguszewski; Jerzy R Ladny Journal: Resuscitation Date: 2020-04-15 Impact factor: 5.262
Authors: Carsten Lott; Anatolij Truhlář; Anette Alfonzo; Alessandro Barelli; Violeta González-Salvado; Jochen Hinkelbein; Jerry P Nolan; Peter Paal; Gavin D Perkins; Karl-Christian Thies; Joyce Yeung; David A Zideman; Jasmeet Soar Journal: Notf Rett Med Date: 2021-06-10 Impact factor: 0.826