Literature DB >> 19853507

Accuracy and reliability of GPS devices for measurement of movement patterns in confined spaces for court-based sports.

Rob Duffield1, Machar Reid, John Baker, Wayne Spratford.   

Abstract

The aim of this study was to assess the accuracy and reliability of global positioning system (GPS) measures of distance and speed, compared to a high-resolution motion analysis system, for confined movement patterns used in many court-based sports. A single male participant performed 10 repetitions of four respective drills replicating court-based movement patterns and six repetitions of a random movement drill that replicated tennis match-play movement patterns. Two 1Hz and two 5Hz GPS devices concurrently measured distance covered and speed of all court-based drills. A 22 camera VICON motion analysis system, operating at 100Hz, tracked the position of an 18mm reflective marker affixed to one of the GPS devices to provide the criterion movement data. Results indicated that both 1 and 5Hz GPS devices under reported distance covered as well as both mean and peak speed compared to the VICON system (P<0.05). The coefficient of variation for both GPS devices for distance and speed measures ranged between 4 and 25%. Further, the faster the speed and more repetitive the movement pattern (over a similar location), the greater the measurement error. The inter-unit reliability for distance and speed measures of both 1 and 5Hz systems for movements in confined spaces was generally low to moderate (r=0.10-0.70). In conclusion, for court-based sports or movements in confined spaces, GPS technology under reports distance covered and both mean and peak speed of movement.

Entities:  

Mesh:

Year:  2009        PMID: 19853507     DOI: 10.1016/j.jsams.2009.07.003

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  35 in total

Review 1.  Measures of rowing performance.

Authors:  T Brett Smith; Will G Hopkins
Journal:  Sports Med       Date:  2012-04-01       Impact factor: 11.136

Review 2.  Gold Standard or Fool's Gold? The Efficacy of Displacement Variables as Indicators of Energy Expenditure in Team Sports.

Authors:  Ted Polglaze; Brian Dawson; Peter Peeling
Journal:  Sports Med       Date:  2016-05       Impact factor: 11.136

Review 3.  Sprint Running Performance Monitoring: Methodological and Practical Considerations.

Authors:  Thomas Haugen; Martin Buchheit
Journal:  Sports Med       Date:  2016-05       Impact factor: 11.136

4.  Field-based pre-cooling for on-court tennis conditioning training in the heat.

Authors:  Rob Duffield; Stephen P Bird; Robert J Ballard
Journal:  J Sports Sci Med       Date:  2011-06-01       Impact factor: 2.988

5.  Reliability and Accuracy of 10 Hz GPS Devices for Short-Distance Exercise.

Authors:  Julen Castellano; David Casamichana; Julio Calleja-González; Jaime San Román; Sergej M Ostojic
Journal:  J Sports Sci Med       Date:  2011-03-01       Impact factor: 2.988

6.  The Validity and Reliability of Wearable Microtechnology for Intermittent Team Sports: A Systematic Review.

Authors:  Zachary L Crang; Grant Duthie; Michael H Cole; Jonathon Weakley; Adam Hewitt; Rich D Johnston
Journal:  Sports Med       Date:  2020-12-24       Impact factor: 11.136

7.  The Accuracy of a Low-Cost GPS System during Football-Specific Movements.

Authors:  Emiel Schulze; Ross Julian; Sabrina Skorski
Journal:  J Sports Sci Med       Date:  2021-03-01       Impact factor: 2.988

8.  Training Load Monitoring in Team Sports: A Novel Framework Separating Physiological and Biomechanical Load-Adaptation Pathways.

Authors:  Jos Vanrenterghem; Niels Jensby Nedergaard; Mark A Robinson; Barry Drust
Journal:  Sports Med       Date:  2017-11       Impact factor: 11.136

9.  Effect of Court Dimensions on Players' External and Internal Load during Small-Sided Handball Games.

Authors:  Matteo Corvino; Antonio Tessitore; Carlo Minganti; Marko Sibila
Journal:  J Sports Sci Med       Date:  2014-05-01       Impact factor: 2.988

10.  Criterion validity and accuracy of global positioning satellite and data logging devices for wheelchair tennis court movement.

Authors:  Paul Sindall; John P Lenton; Katie Whytock; Keith Tolfrey; Michelle L Oyster; Rory A Cooper; Victoria L Goosey-Tolfrey
Journal:  J Spinal Cord Med       Date:  2013-07       Impact factor: 1.985

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.