BACKGROUND: The Sorin Memo 3D (Sorin Biomedica Cardio S.r.L., Saluggia, Italy) is a new, complete semirigid annuloplasty ring. Clinical use, outcomes, and echocardiographic results are reported as an evaluation of its safety and efficacy in the treatment of mitral valve regurgitation (MVR).
METHODS: This device was assessed in 63 patients (63.5% men; mean age, 70.2 +/- 10.3 years) who underwent MVR operations between January 2007 and June 2008. Functional classification was normal leaflet motion (type I; 1.6%), leaflet prolapse (type II; 66.7%), and restricted leaflet motion (type III; 31.7%). Valve disease was degenerative (68.25%), ischemic (25.4%), and nonischemic dilated cardiomyopathy (6.35%).
RESULTS: Early mortality (< or = 30 days) was 3.3% (2 patients). Late mortality (11.2 +/- 5.1 months) was 4.9% (3 patients). No deaths were device-related. Thromboembolic stroke occurred in 3.3% and endocarditis in 1.6%. Freedom from reoperation was 98.4%. At 6 months, MVR was grade 0/1 in 93.7% and grade 2+ in 6.4%. Left end-diastolic ventricular diameters decreased significantly from 59.3 +/- 6.9 mm preoperatively to 50.6 +/- 12.2 mm at 6 months, pulmonary arterial pressure decreased from 44.8 +/- 7.1 mm Hg to 38.4 +/- 5.5 mm Hg, and left ventricular ejection fraction increased significantly from 0.469 +/- 0.129 to 0.582 +/- 0.106. New York Heart Association functional class was I in 81% and II in 13.8%.
CONCLUSIONS: Early results indicate the Sorin Memo 3D ring safely and effectively minimizes secondary MVR resulting from all causes and preserves mitral annular flexibility and function at follow-up.

Entities:  

Mesh:

Year:  2009        PMID: 19853099     DOI: 10.1016/j.athoracsur.2009.07.017

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Annular dynamics after mitral valve repair with different prosthetic rings: A real-time three-dimensional transesophageal echocardiography study.

Authors:  Hiroyuki Nishi; Koichi Toda; Shigeru Miyagawa; Yasushi Yoshikawa; Satsuki Fukushima; Masashi Kawamura; Daisuke Yoshioka; Tetsuya Saito; Takayoshi Ueno; Toru Kuratani; Yoshiki Sawa
Journal:  Surg Today       Date:  2015-12-21       Impact factor: 2.549

2.  Comparison of saddle-shape flexibility and elliptical-shape stability between Cosgrove-Edwards and Memo-3D annuloplasty rings using three-dimensional analysis software.

Authors:  Akira Tsuneto; Kiyoyuki Eishi; Takashi Miura; Kazuyoshi Tanigawa; Seiji Matsukuma; Takako Minami; Yuji Koide; Satoshi Ikeda; Hiroaki Kawano; Koji Maemura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-04-06

3.  Annular dynamics of memo3D annuloplasty ring evaluated by 3D transesophageal echocardiography.

Authors:  Hiroyuki Nishi; Koichi Toda; Shigeru Miyagawa; Yasushi Yoshikawa; Satsuki Fukushima; Daisuke Yoshioka; Yoshiki Sawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-01-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.