Literature DB >> 19849775

Retention of zirconia copings on zirconia implant abutments cemented with provisional luting agents.

Y Kokubo1, T Kano, M Tsumita, S Sakurai, A Itayama, S Fukushima.   

Abstract

The purpose of this study is to measure and compare the retentive force of zirconia-based all-ceramic crowns cemented on zirconia abutments using five provisional luting agents. In addition, the effect of sandblasting and thermocycling on the retentive force was evaluated. Two hundred zirconia abutments and copings were fabricated (Procera system; Nobel Biocare) and divided into five groups. Hy bond temporary cement hard (Hard), Hy bond temporary cement soft (Soft), experimental temporary cement (New), Tempbond NE (Temp) and Freegenool temporary pack (Pack) were used according to the manufacturers' instructions. Each group was divided into two groups, one with and one without sandblasting. Furthermore, thermocycling up to 2000 cycles was conducted on half of each group. After 24 h and thermocycling, the retentive force was measured using a universal testing machine. The data were subjected to analysis of variance, and comparisons of the means were performed with a Games-Howell test at a level of 95%. As a result, Hard showed the highest retentive force, sandblasting was effective for improving the durability, and no effect of sandblasting was detected in the others. New showed stability of the retentive force even after thermocycling. The retentive force of Temp and Pack decreased significantly after thermocycling even with sandblasting. The retentive forces were different from the provisional cement and sandblasting, and Temp and Pack may not be appropriate for the retention of single-tooth zirconia abutments and coping restorations.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19849775     DOI: 10.1111/j.1365-2842.2009.02013.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  6 in total

1.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

2.  Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.

Authors:  Marzieh Alikhasi; Ahmad Rohanian; Safoura Ghodsi; Amin Mohammadpour Kolde
Journal:  Eur J Dent       Date:  2018 Jan-Mar

3.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20

4.  Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation.

Authors:  Matthias Rödiger; Sven Rinke; Fenja Ehret-Kleinau; Franziska Pohlmeyer; Katharina Lange; Ralf Bürgers; Nikolaus Gersdorff
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

5.  Assessment and comparison of retention of zirconia copings luted with different cements onto zirconia and titanium abutments: An in vitro study.

Authors:  Neelima Sreekumar Menon; G P Surendra Kumar; K R Jnanadev; C L Satish Babu; Shilpa Shetty
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

6.  Effects of crown retrieval on implants and the surrounding bone: a finite element analysis.

Authors:  Serhat Emre Ozkir; Server Mutluay Unal; Emel Yurekli; Sedat Güven
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  6 in total