Abstract

Recent studies have shown that amphetamines and other drugs of abuse residues occur in wastewater. Consequently, several methods have been developed for their determination by solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, a major drawback of these methods is the lack of selectivity during SPE that results in reduced sensitivity, due to matrix effects, and in some cases in low precision and poor accuracy. In order to tackle this problem, three different SPE alternatives have been evaluated in this work for the determination of five amphetamines: common hydrophilic balance (Oasis HLB), mixed-mode (Oasis MCX) and molecularly imprinted polymers (MIPs) sorbents. Among them, Oasis HLB showed the worst performance, as three amphetamines (MDA, MDMA and MDEA) could not be determined because of interfering signals in the LC-MS/MS chromatogram, and amphetamine recoveries could not be corrected by the use of the deuterated analogue internal standard. Oasis MCX permitted the determination of all target analytes, but with still strong signal suppression: ca. 70% signal drop with wastewater samples, which could in this case be corrected by the internal standards providing acceptable trueness (overall recoveries: 101-137%), precision (RSD: 2.0-12%) and limits of detection (LOD: 1.5-4.4 ng/L). Alternatively, MIPs rendered cleaner extracts with less matrix effects (ca. 30% signal drop), and thus lower LODs (0.5-2.7 ng/L) and even better trueness (91-114% overall recovery) and precision (1.5-4.4%RSD). The final application of the method with MIP cartridges showed the presence of MDA and MDMA in the seven analysed wastewaters at the 4-20 ng/L level.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19846101     DOI: 10.1016/j.chroma.2009.09.069

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

Review 1.  New trends in the analytical determination of emerging contaminants and their transformation products in environmental waters.

Authors:  Ana Agüera; María Jesús Martínez Bueno; Amadeo R Fernández-Alba
Journal:  Environ Sci Pollut Res Int       Date:  2013-03-01       Impact factor: 4.223

2.  Stimulus-responsive hydrogels: Theory, modern advances, and applications.

Authors:  Michael C Koetting; Jonathan T Peters; Stephanie D Steichen; Nicholas A Peppas
Journal:  Mater Sci Eng R Rep       Date:  2015-05-16       Impact factor: 36.214

Review 3.  Mass spectrometric strategies for the investigation of biomarkers of illicit drug use in wastewater.

Authors:  Félix Hernández; Sara Castiglioni; Adrian Covaci; Pim de Voogt; Erik Emke; Barbara Kasprzyk-Hordern; Christoph Ort; Malcolm Reid; Juan V Sancho; Kevin V Thomas; Alexander L N van Nuijs; Ettore Zuccato; Lubertus Bijlsma
Journal:  Mass Spectrom Rev       Date:  2016-10-17       Impact factor: 10.946

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.