Literature DB >> 19838419

Why 'the bigger the better' is not always the case when utilising microelectrode arrays: high density vs. low density arrays for the electroanalytical sensing of chromium(VI).

Sebastian J Hood1, Dimitrios K Kampouris, Rashid O Kadara, Norman Jenkinson, F Javier del Campo, Francesc Xavier Muñoz, Craig E Banks.   

Abstract

We demonstrate, with the example of the electroanalytical sensing of chromium(vi) using ultra-microelectrode arrays, that a larger number of microelectrodes comprising an array do not necessarily provide improved electroanalytical performance. Using a low density array, which consists of 256 microdiscs where each microdisc comprising the array has a radius of 10 microns in a cubic arrangement separated from their nearest neighbour by 100 microns, the electroanalytical sensing of chromium(vi) is shown to be possible over the range 13-428 microM with a limit of detection of 3.4 microM readily achievable. Using a high density microelectrode, consisting of 2597 microdiscs where each microdisc has a radius of 2.5 microns in a hexagonal pattern which are separated from their nearest neighbour by 55 microns, the electroanalytical performance, in terms of linear range and sensitivity, is considerably lower going against the misconception that a high density array should produce a superior analytical response. The reason for this disparity is discussed and it is shown that the arrangement of the microelectrodes on the array is critical due to the interaction of diffusion zones between neighbouring electrodes allowing analysts to make informed decisions on the conscientious choice of microelectrode arrays.

Mesh:

Substances:

Year:  2009        PMID: 19838419     DOI: 10.1039/b911507b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

Review 1.  Micro/Nano Electrode Array Sensors: Advances in Fabrication and Emerging Applications in Bioanalysis.

Authors:  Yang Liu; Xiuting Li; Jie Chen; Chonglin Yuan
Journal:  Front Chem       Date:  2020-11-13       Impact factor: 5.221

2.  Development of a sticker sealed microfluidic device for in situ analytical measurements using synchrotron radiation.

Authors:  Itamar T Neckel; Lucas F de Castro; Flavia Callefo; Verônica C Teixeira; Angelo L Gobbi; Maria H Piazzetta; Ricardo A G de Oliveira; Renato S Lima; Rafael A Vicente; Douglas Galante; Helio C N Tolentino
Journal:  Sci Rep       Date:  2021-12-08       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.