Literature DB >> 19836941

Potential of a simplified measurement scheme and device structure for a low cost label-free point-of-care capacitive biosensor.

Elder A de Vasconcelos1, Newton G Peres, Cintya O Pereira, Valdinete L da Silva, Eronides F da Silva, Rosa F Dutra.   

Abstract

A simplified measurement scheme and device structure aiming at developing a low cost, label-free, point-of-care capacitive biosensor were investigated. The detection principle is the increase of low frequency capacitance between two planar Al electrodes observed after antibody-antigen interaction. The electrodes, deposited on oxidized Si wafers, were covered with an antibody layer, with and without using self-assembled thiol monolayer. Immunoglobulin G (IgG) and cardiac troponin T (TnT) were used as analytes to asses this proposal. The device was able to detect successfully TnT levels in the range 0.07 to 6.83ng/mL in human serum from patients with cardiac diseases and in the range 0.01ng/mL to 5ng/mL for TnT in phosphate buffer saline. An equivalent circuit model able to reproduce the general behavior of experimental capacitance versus frequency curves was presented. The investigated features that have potential to reduce costs and simplify measurements were: use of single, low frequency (1kHz) measurement signal, within the range of low cost portable capacitance meters; employment of a lower cost electrode material, aluminum, instead of gold electrodes; and use of simple and miniaturized planar two-electrodes arrangement, thus making a portable system for point-of-care applications.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19836941     DOI: 10.1016/j.bios.2009.08.050

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Piezoelectric point-of-care biosensor for the detection of SARS-COV-2 (COVID-19) antibodies.

Authors:  Debdyuti Mandal; Mustahseen M Indaleeb; Alexandra Younan; Sourav Banerjee
Journal:  Sens Biosensing Res       Date:  2022-07-14

2.  Flexible electrical aptasensor using dielectrophoretic assembly of graphene oxide and its subsequent reduction for cardiac biomarker detection.

Authors:  Abhinav Sharma; Jaesung Jang
Journal:  Sci Rep       Date:  2019-04-12       Impact factor: 4.379

Review 3.  Use of Cysteamine and Glutaraldehyde Chemicals for Robust Functionalization of Substrates with Protein Biomarkers-An Overview on the Construction of Biosensors with Different Transductions.

Authors:  Rodica Elena Ionescu
Journal:  Biosensors (Basel)       Date:  2022-07-29

4.  Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate.

Authors:  Zachary T Johnson; Nathan Jared; John K Peterson; Jingzhe Li; Emily A Smith; Scott A Walper; Shelby L Hooe; Joyce C Breger; Igor L Medintz; Carmen Gomes; Jonathan C Claussen
Journal:  Glob Chall       Date:  2022-07-26

Review 5.  CMOS cell sensors for point-of-care diagnostics.

Authors:  Yekbun Adiguzel; Haluk Kulah
Journal:  Sensors (Basel)       Date:  2012-07-25       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.