Literature DB >> 19836825

Variable bacterial load of Legionella spp. in a hospital water system.

Christian Napoli1, Roberta Iatta, Fabrizio Fasano, Teresa Marsico, Maria Teresa Montagna.   

Abstract

Several approved protocols for the prevention of Legionella pneumonia base the type of intervention (to disinfect or not) on the level of contamination found (cfu/L). However, if the level of contamination by Legionella spp. of a water system fluctuates in a short period of time, inadequate sampling could lead to different decisions being made. To determine if there are significant variations in the bacterial count of Legionella spp., water samples were taken at different times from the same sites. Eight wards were selected from a large hospital in Southern Italy and a water sample was taken from 21 taps in each ward at the same time each day for 5 consecutive days. A Freidman test detected statistically significant differences in average Legionella spp. load over the 5 sampling days (p value<0.001). This fluctuating load can have practical implications: the Italian Guidelines recommend disinfection only for a Legionella count>10,000 cfu/L in hospitals without documented cases of disease. In the present study, the daily average loads varied, during the 5-day sampling period, above and below this cut-off (10,000 cfu/L). This means that the decision to disinfect or not would be different depending on which day the sampling was carried out. Our data suggest that, especially in health-care facilities, a single sampling would not give a realistic estimation of risk; therefore, even at lower levels of bacterial load, measures should be taken to reduce it further.

Entities:  

Mesh:

Year:  2009        PMID: 19836825     DOI: 10.1016/j.scitotenv.2009.09.039

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  11 in total

Review 1.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

Review 2.  Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review.

Authors:  Hong Wang; Emilie Bédard; Michèle Prévost; Anne K Camper; Vincent R Hill; Amy Pruden
Journal:  Water Res       Date:  2017-03-25       Impact factor: 11.236

3.  Legionella spp. and legionellosis in southeastern Italy: disease epidemiology and environmental surveillance in community and health care facilities.

Authors:  Christian Napoli; Fabrizio Fasano; Roberta Iatta; Giovanna Barbuti; Teresa Cuna; Maria Teresa Montagna
Journal:  BMC Public Health       Date:  2010-11-02       Impact factor: 3.295

4.  Legionella control in the water system of antiquated hospital buildings by shock and continuous hyperchlorination: 5 years experience.

Authors:  Giovanni Battista Orsi; Matteo Vitali; Lucia Marinelli; Veronica Ciorba; Daniela Tufi; Angela Del Cimmuto; Paolo Ursillo; Massimo Fabiani; Susi De Santis; Carmela Protano; Carolina Marzuillo; Maria De Giusti
Journal:  BMC Infect Dis       Date:  2014-07-16       Impact factor: 3.090

5.  Sequence based typing of Legionella pneumophila sg 1 isolated in nosocomial acquired infections in Apulia, Southern Italy.

Authors:  R Iatta; T Cuna; O De Giglio; M T Montagna; C Napoli
Journal:  J Prev Med Hyg       Date:  2013-09

6.  Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

Authors:  Maria Teresa Montagna; Osvalda De Giglio; Maria Luisa Cristina; Christian Napoli; Claudia Pacifico; Antonella Agodi; Tatjana Baldovin; Beatrice Casini; Maria Anna Coniglio; Marcello Mario D'Errico; Santi Antonino Delia; Maria Grazia Deriu; Marco Guida; Pasqualina Laganà; Giorgio Liguori; Matteo Moro; Ida Mura; Francesca Pennino; Gaetano Privitera; Vincenzo Romano Spica; Silvia Sembeni; Anna Maria Spagnolo; Stefano Tardivo; Ida Torre; Federica Valeriani; Roberto Albertini; Cesira Pasquarella
Journal:  Int J Environ Res Public Health       Date:  2017-06-22       Impact factor: 3.390

7.  Management of Microbiological Contamination of the Water Network of a Newly Built Hospital Pavilion.

Authors:  Osvalda De Giglio; Giusy Diella; Marco Lopuzzo; Francesco Triggiano; Carla Calia; Chrysovalentinos Pousis; Fabrizio Fasano; Giuseppe Calabrese; Vincenza Rafaschieri; Lucia Federica Carpagnano; Matilde Carlucci; Loreto Gesualdo; Maria Luisa Ricci; Maria Scaturro; Maria Cristina Rota; Lucia Bonadonna; Luca Lucentini; Maria Teresa Montagna
Journal:  Pathogens       Date:  2021-01-16

Review 8.  Environmental Management of Legionella in Domestic Water Systems: Consolidated and Innovative Approaches for Disinfection Methods and Risk Assessment.

Authors:  Emanuele Luigi Sciuto; Pasqualina Laganà; Simona Filice; Silvia Scalese; Sebania Libertino; Domenico Corso; Giuseppina Faro; Maria Anna Coniglio
Journal:  Microorganisms       Date:  2021-03-11

9.  Four-Year Environmental Surveillance Program of Legionella spp. in One of Palermo's Largest Hospitals.

Authors:  Ignazio Arrigo; Elena Galia; Teresa Fasciana; Orazia Diquattro; Maria Rita Tricoli; Nicola Serra; Mario Palermo; Anna Giammanco
Journal:  Microorganisms       Date:  2022-04-01

10.  Rapid detection of total and viable Legionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry.

Authors:  Hans-Anton Keserue; Andreas Baumgartner; Richard Felleisen; Thomas Egli
Journal:  Microb Biotechnol       Date:  2012-11       Impact factor: 5.813

View more