Literature DB >> 19835324

Intrastromal correction of presbyopia using a femtosecond laser system.

Luis Antonio Ruiz1, Liliana Marcela Cepeda, Vanessa Carolina Fuentes.   

Abstract

PURPOSE: To introduce a new, minimally invasive intrastromal correction for presbyopia (INTRACOR procedure) using the TECHNOLAS femtosecond laser system (Technolas Perfect Vision GmbH).
METHODS: The INTRACOR procedure was performed in 83 eyes of 45 patients aged 44 to 67 years. Follow-up was 6 to 12 months. Data recorded included age; pre- and postoperative refraction; uncorrected distance (UDVA), intermediate, and near visual acuity (UNVA); corrected distance visual acuity (CDVA); distance corrected near visual acuity; corneal hysteresis (CH), corneal resistance factor (CRF), and asphericity; pachymetry; endothelial cell density; contrast sensitivity; and ocular aberrations.
RESULTS: At 6 months postoperatively, all 83 (100%) eyes had improved UNVA, with minimal or no change in UDVA. Twenty-two eyes were available at 12 months; UNVA improved to J1 in these eyes with continued improvement in mean UDVA. At last follow-up, a mild myopic shift in refraction was noted with only 3 (3.6%) eyes showing a 2- or 3-line decrease of UDVA, and 74 (89.2%) eyes achieved both J2 and 20/25 or better. Mean CDVA and distance corrected near visual acuity continued to improve with time. Two (2.4%) eyes lost 2 lines of CDVA at 6 months, but this did not occur in the 22 eyes seen at 1 year. Overall stability was noted in CH, CRF, pachymetry, endothelial cell density, and contrast sensitivity. Primary spherical aberrations shifted toward negative values and secondary spherical aberration shifted toward positive values. No corneal structural complications were observed.
CONCLUSIONS: The INTRACOR intrastromal procedure using the TECHNOLAS femtosecond laser is a promising procedure for presbyopia correction. It preserves the corneal epithelium and anterior stromal fibers. Copyright 2009, SLACK Incorporated.

Entities:  

Mesh:

Year:  2009        PMID: 19835324     DOI: 10.3928/1081597X-20090917-05

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  15 in total

1.  Radial intrastromal femtosecond laser incisions for myopia correction.

Authors:  Zhen-Yong Zhang; Matthew R Hoffman; Xing-Ru Zhang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-01-12       Impact factor: 3.117

Review 2.  Femtosecond laser in refractive and cataract surgeries.

Authors:  Han-Han Liu; Ying Hu; Hong-Ping Cui
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

3.  [Agreement of subjective and objective refraction measurements following INTRACOR femtosecond laser treatment].

Authors:  A Fitting; A Ehmer; T M Rabsilber; G U Auffarth; M P Holzer
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

4.  [Intrastromal femtosecond laser-based presbyopia correction].

Authors:  M P Holzer
Journal:  Ophthalmologe       Date:  2013-03       Impact factor: 1.059

5.  Assessment of contrast sensitivity loss after intrastromal femtosecond laser and LASIK procedure.

Authors:  Elsa L C Mai; Ie-Bin Lian; David C K Chang
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

6.  [Effect of intrastromal correction of presbyopia with femtosecond laser (INTRACOR) on mesopic contrast sensitivity].

Authors:  A Fitting; N Menassa; G U Auffarth; M P Holzer
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

7.  [Functional results after bilateral intrastromal femtosecond laser correction of presbyopia].

Authors:  R Khoramnia; M P Holzer; A Fitting; G U Auffarth; T M Rabsilber
Journal:  Ophthalmologe       Date:  2013-12       Impact factor: 1.059

8.  Ultrashort-pulse lasers treating the crystalline lens: will they cause vision-threatening cataract? (An American Ophthalmological Society thesis).

Authors:  Ronald R Krueger; Harvey Uy; Jared McDonald; Keith Edwards
Journal:  Trans Am Ophthalmol Soc       Date:  2012-12

9.  Surgical management of presbyopia.

Authors:  André Am Torricelli; Jackson B Junior; Marcony R Santhiago; Samir J Bechara
Journal:  Clin Ophthalmol       Date:  2012-09-06

10.  In vivo biocompatibility of two PEG/PAA interpenetrating polymer networks as corneal inlays following deep stromal pocket implantation.

Authors:  Xiao Wei Tan; Laura Hartman; Kim Peng Tan; Rebekah Poh; David Myung; Luo Luo Zheng; Dale Waters; Jaan Noolandi; Roger W Beuerman; Curtis W Frank; Christopher N Ta; Donald T H Tan; Jodhbir S Mehta
Journal:  J Mater Sci Mater Med       Date:  2013-01-26       Impact factor: 3.896

View more