Literature DB >> 19835301

Cup positioning in primary total hip arthroplasty using an imageless navigation device: is there a learning curve?

Fritz Thorey1, Phillip Klages, Matthias Lerch, Thilo Floerkemeier, Henning Windhagen, Gabriela von Lewinski.   

Abstract

In this study, the success of cup positioning in total hip arthroplasty (THA) using an imageless navigation system was analyzed (1) during the learning period and (2) after the learning period for using the navigation system. Sixty THAs were performed in which threaded cups were placed with use of a computer-assisted navigation device (B. Braun Aesculap, Tuttlingen, Germany). Half of the procedures (30), group A, were done by the same surgeons under the learning curve for using the navigation system; the other half (30), group B, were done by surgeons who were no longer considered under the learning curve. Intraoperative acetabular component parameters (inclination, anteversion) for both groups were compared with postoperative radiographic alignment values. In group A, significant differences were seen between intraoperative and postoperative cup orientation. In group B, no significant differences were seen between intraoperative and postoperative cup orientation. Additionally, the percentage of outliers decreased in group B. Operating and anesthesia times significantly decreased with the surgeon's experience in imageless cup navigation. There was an individual increase of precision during the learning curve for all surgeons. Imageless navigation is a dependable and accurate method of cup positioning during THA. However, accuracy of cup placement and length of operating room time were affected by surgeons' experience using the system. Imageless navigation may lead to a reduction in the length of the learning curve for surgeons beginning to perform THAs, improvement in the surgeon's ability to perform this procedure safely, and minimization of outliers. Copyright 2009, SLACK Incorporated.

Entities:  

Mesh:

Year:  2009        PMID: 19835301     DOI: 10.3928/01477447-20090915-52

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Evaluation of the surgical learning curve for I-125 episcleral plaque placement for the treatment of posterior uveal melanoma: a two decade review.

Authors:  Nisha V Shah; Samuel K Houston; Timothy G Murray; Arnold M Markoe
Journal:  Clin Ophthalmol       Date:  2012-03-20

2.  The etiology of revision total hip arthroplasty: current trends in a retrospective survey of 3450 cases.

Authors:  Jonas Kummerant; Nils Wirries; Alexander Derksen; Stefan Budde; Henning Windhagen; Thilo Floerkemeier
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-30       Impact factor: 2.928

3.  Imageless navigation total hip arthroplasty - an evaluation of operative time.

Authors:  Epaminondas Markos Valsamis; David Ricketts; Adnan Hussain; Amir-Reza Jenabzadeh
Journal:  SICOT J       Date:  2018-05-23

4.  Minimal Increase in Total Hip Arthroplasty Surgical Procedural Time with the Use of a Novel Surgical Navigation Tool.

Authors:  Alexander Christ; Danielle Ponzio; Michael Pitta; Kaitlin Carroll; Jeffrey M Muir; Peter K Sculco
Journal:  Open Orthop J       Date:  2018-09-28
  4 in total