Literature DB >> 19829793

Use of haemostatic matrix in management of rectus hematoma in an anticoagulated patient: a case report.

Kansav Tunc Kizilkanat1, Engin Olcucuoglu, Hakan Kulacoglu.   

Abstract

Rectus sheath hematoma may present as a painful mass in the anterior abdominal wall. The underlying reasons may vary, while anticoagulant use and thromboembolism prophylaxis are documented causes. Treatment is mostly conservative however interventional procedures can be required. We herein present a case of 76-year-old patient with an uncontrolled rectus hematoma despite surgical hemostasis. The patient was treated succesfully by applying hemostatic matrix (Floseal).

Entities:  

Year:  2009        PMID: 19829793      PMCID: PMC2740183          DOI: 10.4076/1757-1626-2-6353

Source DB:  PubMed          Journal:  Cases J        ISSN: 1757-1626


  13 in total

1.  Use of FloSeal haemostatic gel in massive obstetric haemorrhage: a case report.

Authors:  K T Moriarty; S Premila; P J Bulmer
Journal:  BJOG       Date:  2008-03-19       Impact factor: 6.531

2.  Use of FloSeal matrix hemostatic agent in partial splenectomy after penetrating trauma.

Authors:  Mike J Stacey; Raj S Rampaul; Arvind Rengaragan; John P Duffy; Robert D Macmillan
Journal:  J Trauma       Date:  2008-02

Review 3.  Spontaneous hematoma of the rectus abdominis sheath: a review of 177 cases with report of 7 personal cases.

Authors:  M M Linhares; G J Lopes Filho; P C Bruna; A B Ricca; N Y Sato; M Sacalabrini
Journal:  Int Surg       Date:  1999 Jul-Sep

4.  Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in patients with acute anterior epistaxis.

Authors:  Ronald A Mathiasen; Raul M Cruz
Journal:  Laryngoscope       Date:  2005-05       Impact factor: 3.325

5.  Rectus sheath hematoma: review of 126 cases at a single institution.

Authors:  W Brett Cherry; Paul S Mueller
Journal:  Medicine (Baltimore)       Date:  2006-03       Impact factor: 1.889

6.  Prospective, randomized, controlled clinical trial of a novel matrix hemostatic sealant in children undergoing adenoidectomy.

Authors:  Ronald A Mathiasen; Raul M Cruz
Journal:  Otolaryngol Head Neck Surg       Date:  2004-11       Impact factor: 3.497

7.  Does topical haemostatic agent have an adverse effect on the function of the prostatic neurovascular bundle?

Authors:  Ilia Zeltser; Daniel Dugi; Amit Gupta; Sangtae Park; Wareef Kabbani; Jeffrey Cadeddu
Journal:  BJU Int       Date:  2008-06-28       Impact factor: 5.588

8.  Haematoma of the rectus abdominis muscle.

Authors:  H J Verhagen; P L Tolenaar; R Sybrandy
Journal:  Eur J Surg       Date:  1993 Jun-Jul

9.  Efficacy of a haemostatic matrix for the management of bleeding in patients undergoing liver resection: results from 237 cases.

Authors:  Francesco Izzo; Raimondo Di Giacomo; Paolo Falco; Mauro Piccirillo; Rossana Iodice; Antonio Pio Orlando; Pasquale Aprea; Francesco Cremona; Massimiliano Di Marzo; Domenico Nicola Idà; Angelo A Mastro; Steven A Curley
Journal:  Curr Med Res Opin       Date:  2008-02-19       Impact factor: 2.580

10.  Feasibility of the use of novel matrix hemostatic sealant (FloSeal) to achieve hemostasis during laparoscopic excision of endometrioma.

Authors:  Roberto Angioli; Ludovico Muzii; Roberto Montera; Patrizio Damiani; Filippo Bellati; Francesco Plotti; Marzio Angelo Zullo; Irma Oronzi; Corrado Terranova; Pierluigi Benedetti Panici
Journal:  J Minim Invasive Gynecol       Date:  2009-01-09       Impact factor: 4.137

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.